Film Condensation of Potassium Using Copper Condensing Block for Precise Wall-Temperature Measurement

[+] Author and Article Information
Stanley J. Wilcox

E. I. duPont de Nemours & Co. Inc., Wilmington, Del.

Warren M. Rohsenow

Massachusetts Institute of Technology, Cambridge, Mass.

J. Heat Transfer 92(3), 359-371 (Aug 01, 1970) (13 pages) doi:10.1115/1.3449671 History: Received July 07, 1969; Online August 11, 2010

Abstract

Major differences exist in results published by investigators of film condensation of liquid metal vapors. In particular, the reported dependence of the condensation coefficient on pressure has raised questions about both the precision of the reported data and the validity of the basic interphase mass transfer analysis. An error analysis presented in this investigation indicates that the reported pressure dependence of the condensation coefficient at higher pressures is due to an inherent limitation in the precision of the condensing wall temperature measurement. The magnitude of this limitation in precision is different for the various test systems used. The analysis shows, however, that the primary variable affecting the precision of the wall temperature measurement is the thermal conductivity of the condensing block. To verify the analysis, potassium was condensed on a vertical surface of a copper condensing block. The copper block was protected from the potassium with nickel plating. Condensation coefficients near unity were obtained up to higher pressures than those previously reported for potassium condensed with stainless steel or nickel condensing blocks. These experimental results agree with the prediction of the error analysis. In addition, a discussion of the precautions used to eliminate the undesirable effects of both noncondensable gas and improper thermocouple technique is included. It is concluded from the experimental data and the error analysis that the condensation coefficient is equal to unity and that the pressure dependence reported by others is due to experimental error.

Copyright © 1970 by ASME
Your Session has timed out. Please sign back in to continue.

References

Figures

Tables

Errata

Discussions

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging and repositioning the boxes below.

Related Journal Articles
Related eBook Content
Topic Collections

Sorry! You do not have access to this content. For assistance or to subscribe, please contact us:

  • TELEPHONE: 1-800-843-2763 (Toll-free in the USA)
  • EMAIL: asmedigitalcollection@asme.org
Sign In