0
RESEARCH PAPERS

Critical Heat Flux During Natural Convective Boiling in Vertical Rectangular Channels Submerged in Saturated Liquid

[+] Author and Article Information
M. Monde, H. Kusuda, H. Uehara

Department of Mechanical Engineering, Saga University, Honjo-machi, Saga City, Saga, Japan 840

J. Heat Transfer 104(2), 300-303 (May 01, 1982) (4 pages) doi:10.1115/1.3245087 History: Received May 15, 1981; Online October 20, 2009

Abstract

An experimental study of the critical heat flux has been carried out for natural convective boiling at atmospheric pressure in vertical rectangular channels. Experiments in four kinds of test liquids (water, ethanol, freon 113, and benzene) have been made for the ratio l/s less than 120, in which l is the length of the heated surface and s is the width of the channels. A generalized correlation for the critical heat-flux data in the four test liquids is evolved.