Heat Transfer and Pressure Drop in a Helically Coiled Rectangular Duct

[+] Author and Article Information
V. Kadambi

Corporate Research and Development, General Electric Company, Schenectady, NY 12301

E. K. Levy, S. Neti

Department of Mechanical Engineering and Mechanics, Lehigh University, Bethlehem, PA 18017

J. Heat Transfer 108(2), 343-349 (May 01, 1986) (7 pages) doi:10.1115/1.3246927 History: Received March 16, 1984; Online October 20, 2009

Abstract

The present paper deals with experiments using air in three helically coiled rectangular ducts of mean diameters 12.7 cm, 17.8 cm, and 22.8 cm, respectively, made of rectangular wave-guide tubing of dimensions 1.27 cm × 0.64 cm. Pressure variations observed around the ducts were qualitatively in agreement with the expectations for secondary flow. The friction factors change gradually with increasing Reynolds numbers over the range 1200–10,000 without exhibiting a sudden transition from laminar flow to turbulence. At all Reynolds numbers, these are higher than those for a straight duct by 20–100 percent. The heat transfer coefficient is also higher than that for straight ducts ranging between 20–300 percent, depending on the Reynolds number. The largest increases are seen in the Reynolds number range 1200–2500.

Copyright © 1986 by ASME
Your Session has timed out. Please sign back in to continue.

References

Figures

Tables

Errata

Discussions

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging and repositioning the boxes below.

Related Journal Articles
Related eBook Content
Topic Collections

Sorry! You do not have access to this content. For assistance or to subscribe, please contact us:

  • TELEPHONE: 1-800-843-2763 (Toll-free in the USA)
  • EMAIL: asmedigitalcollection@asme.org
Sign In