A summary of a comprehensive experimental study on flow boiling heat transfer is presented for five refrigerants (R134a, R123, R402A, R404A, and R502) evaporating inside plain, horizontal, copper tube test sections. The test data were obtained for both 12.00 mm and 10.92 mm diameters using hot water as the heating source. Besides confirming known trends in flow boiling heat transfer data as a function of test variables, it was also proven that the heat flux level at the dryout point at the top of the tube in annular flow has a very significant downstream effect on heat transfer coefficients in the annular flow regime with partial dryout.

Copyright © 1998 by The American Society of Mechanical Engineers
Your Session has timed out. Please sign back in to continue.

References

Figures

Tables

Errata

Discussions

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging and repositioning the boxes below.

Related Journal Articles
Related eBook Content
Topic Collections

Sorry! You do not have access to this content. For assistance or to subscribe, please contact us:

  • TELEPHONE: 1-800-843-2763 (Toll-free in the USA)
  • EMAIL: asmedigitalcollection@asme.org
Sign In