The coherent gradient sensor (CGS) is a shearing interferometer which has been proposed for the rapid, full-field measurement of deformation states (slopes and curvatures) in thin film-wafer substrate systems, and for the subsequent inference of stresses in the thin films. This approach needs to be verified using a more well-established but time-consuming grain orientation and stress measurement tool, X-ray microdiffraction (XRD). Both CGS and XRD are used to measure the deformation state of the same W film/Si wafer at room temperature. CGS provides a global, wafer-level measurement of slopes while XRD provides a local micromeasurement of lattice rotations. An extreme case of a circular Si wafer with a circular W film island in its center is used because of the presence of discontinuous system curvatures across the wafer. The results are also compared with a theoretical model based on elastic plate analysis of the axisymmetric biomaterial film-substrate system. Slope and curvature measurements by XRD and by CGS compare very well with each other and with theory. The favorable comparison demonstrates that wafer-level CGS metrology provides a quick and accurate alternative to other measurements. It also demonstrates the accuracy of plate theory in modeling thin film-substrate systems, even in the presence of curvature discontinuities
Skip Nav Destination
e-mail: mabrown@Caltech.edu
Article navigation
September 2006
Technical Papers
A Comparison of X-Ray Microdiffraction and Coherent Gradient Sensing in Measuring Discontinuous Curvatures in Thin Film: Substrate Systems
Michal A. Brown,
Michal A. Brown
Department of Materials Science,
e-mail: mabrown@Caltech.edu
California Institute of Technology
, M/C 205-45, Pasadena, CA 91125
Search for other works by this author on:
Tae-Soon Park,
Tae-Soon Park
Oraxion Diagnostics
, 3077 Skyway Court, Fremont, CA 94539
Search for other works by this author on:
Ares Rosakis,
Ares Rosakis
Graduate Aeronautical Laboratories,
California Institute of Technology
, Pasadena, CA 91125
Search for other works by this author on:
Ersan Ustundag,
Ersan Ustundag
Department of Materials Science and Engineering,
Iowa State University
, 2220 Hoover Hall, Ames, IA 50011
Search for other works by this author on:
Young Huang,
Young Huang
Department of Mechanical Engineering,
University of Illinois at Urbana-Champaign
, Urbana, IL 61801
Search for other works by this author on:
Nobumichi Tamura,
Nobumichi Tamura
Advanced Light Source,
Lawrence Berkeley National Laboratory
, 1 Cyclotron Road, Berkeley, CA 94720
Search for other works by this author on:
Bryan Valek
Bryan Valek
Advanced Light Source,
Lawrence Berkeley National Laboratory
, 1 Cyclotron Road, Berkeley, CA 94720
Search for other works by this author on:
Michal A. Brown
Department of Materials Science,
California Institute of Technology
, M/C 205-45, Pasadena, CA 91125e-mail: mabrown@Caltech.edu
Tae-Soon Park
Oraxion Diagnostics
, 3077 Skyway Court, Fremont, CA 94539
Ares Rosakis
Graduate Aeronautical Laboratories,
California Institute of Technology
, Pasadena, CA 91125
Ersan Ustundag
Department of Materials Science and Engineering,
Iowa State University
, 2220 Hoover Hall, Ames, IA 50011
Young Huang
Department of Mechanical Engineering,
University of Illinois at Urbana-Champaign
, Urbana, IL 61801
Nobumichi Tamura
Advanced Light Source,
Lawrence Berkeley National Laboratory
, 1 Cyclotron Road, Berkeley, CA 94720
Bryan Valek
Advanced Light Source,
Lawrence Berkeley National Laboratory
, 1 Cyclotron Road, Berkeley, CA 94720J. Appl. Mech. Sep 2006, 73(5): 723-729 (7 pages)
Published Online: October 14, 2005
Article history
Received:
March 18, 2005
Revised:
October 14, 2005
Citation
Brown, M. A., Park, T., Rosakis, A., Ustundag, E., Huang, Y., Tamura, N., and Valek, B. (October 14, 2005). "A Comparison of X-Ray Microdiffraction and Coherent Gradient Sensing in Measuring Discontinuous Curvatures in Thin Film: Substrate Systems." ASME. J. Appl. Mech. September 2006; 73(5): 723–729. https://doi.org/10.1115/1.2150500
Download citation file:
Get Email Alerts
Mechanics of a Tunable Bistable Metamaterial With Shape Memory Polymer
J. Appl. Mech (January 2025)
Phase Diagrams for Anticlastic and Synclastic Bending Curvatures of Hexagonal and Reentrant Honeycombs
J. Appl. Mech (January 2025)
Nucleation of Fracture: The First-Octant Evidence Against Classical Variational Phase-Field Models
J. Appl. Mech (January 2025)
Related Articles
Measurement of the Axial Residual Stresses Using the Initial Strain Approach
J. Eng. Mater. Technol (January,2000)
Decomposition of Thermal and Mechanical Effects on Microstructure and Hardness of Hard Turned Surfaces
J. Manuf. Sci. Eng (May,2004)
Characterization of Plastic Deformation Induced by Microscale Laser Shock Peening
J. Appl. Mech (September,2004)
Response of Thin Films and Substrate to Micro-Scale Laser Shock Peening
J. Manuf. Sci. Eng (June,2007)
Related Proceedings Papers
Related Chapters
Transient Temperature and Heat Flux Measurement Using Thin-Film Microsensors
Ultrasonic Welding of Lithium-Ion Batteries
The Relation between Cold-Work-Induced Microstructural Evolution and the Postannealing Grain Structures in Zircaloy-4
Zirconium in the Nuclear Industry: 20th International Symposium
Surface Analysis and Tools
Tribology of Mechanical Systems: A Guide to Present and Future Technologies