A minimally diseased (mean intimal thickness = 56 μm) human aortic bifurcation was replicated in rigid and compliant flow-through casts. Both casts were perfused with physiological flow waves having the same Reynolds and unsteadiness numbers; the pulse pressure in the compliant cast produced radial strains similar to those expected from post-mortem measurements of the compliance of the original tissue. The compliant cast was perfused with a Newtonian fluid and one whose rheology was closer to that of blood. Wall shear rate histories were estimated from near-wall velocities obtained by laser Doppler velocimetry at identical sites in both casts. Intimal thickness was measured at corresponding sites in the original vessel and linear regressions were performed between these thicknesses and several normalized shear rate measures obtained from the histories. The correlations showed a positive slope—that is, the intima was thicker at sites exposed to higher shear rates—consistent with earlier results for relatively healthy vessels, but their significance was often poor. There was no significant effect of either model compliance or fluid rheology on the slopes of the correlations of intimal thickness against any normalized shear rate measure.
Skip Nav Destination
Article navigation
August 1992
Research Papers
Effects of Arterial Compliance and Non-Newtonian Rheology on Correlations Between Intimal Thickness and Wall Shear
M. H. Friedman,
M. H. Friedman
Biomedical Engineering Center, The Ohio State University, Columbus, OH 43210
Search for other works by this author on:
C. B. Bargeron,
C. B. Bargeron
Applied Physics Laboratory, The Johns Hopkins University, Laurel, MD 20723
Search for other works by this author on:
D. D. Duncan,
D. D. Duncan
Applied Physics Laboratory, The Johns Hopkins University, Laurel, MD 20723
Search for other works by this author on:
G. M. Hutchins,
G. M. Hutchins
School of Medicine, The Johns Hopkins University, Baltimore, MD 21218
Search for other works by this author on:
F. F. Mark
F. F. Mark
Applied Physics Laboratory, The Johns Hopkins University, Laurel, MD 20723
Search for other works by this author on:
M. H. Friedman
Biomedical Engineering Center, The Ohio State University, Columbus, OH 43210
C. B. Bargeron
Applied Physics Laboratory, The Johns Hopkins University, Laurel, MD 20723
D. D. Duncan
Applied Physics Laboratory, The Johns Hopkins University, Laurel, MD 20723
G. M. Hutchins
School of Medicine, The Johns Hopkins University, Baltimore, MD 21218
F. F. Mark
Applied Physics Laboratory, The Johns Hopkins University, Laurel, MD 20723
J Biomech Eng. Aug 1992, 114(3): 317-320 (4 pages)
Published Online: August 1, 1992
Article history
Received:
December 16, 1991
Revised:
May 6, 1992
Online:
March 17, 2008
Citation
Friedman, M. H., Bargeron, C. B., Duncan, D. D., Hutchins, G. M., and Mark, F. F. (August 1, 1992). "Effects of Arterial Compliance and Non-Newtonian Rheology on Correlations Between Intimal Thickness and Wall Shear." ASME. J Biomech Eng. August 1992; 114(3): 317–320. https://doi.org/10.1115/1.2891389
Download citation file:
Get Email Alerts
Related Articles
Influence of Non-Newtonian Behavior of Blood on Flow in an Elastic Artery Model
J Biomech Eng (February,1996)
A First-Order Mechanical Device to Model Traumatized Craniovascular Biodynamics
J. Med. Devices (March,2007)
Transition to Turbulence Downstream of a Stenosis for Whole Blood and a Newtonian Analog Under Steady Flow Conditions
J Biomech Eng (March,2022)
A Modification of Murray's Law for Shear-Thinning Rheology
J Biomech Eng (May,2015)
Related Chapters
Introduction
Mechanical Blood Trauma in Circulatory-Assist Devices
Two Advanced Methods
Applications of Mathematical Heat Transfer and Fluid Flow Models in Engineering and Medicine
Hemolysis
Mechanical Blood Trauma in Circulatory-Assist Devices