A method for fitting parameters in a poroviscoelastic (PVE) model of articular cartilage in the mouse is presented. Indentation is performed using two different sized indenters and then these data are fitted using a PVE finite element program and parameter extraction algorithm. Data from a smaller indenter, a diameter flat-ended cone, is first used to fit the viscoelastic (VE) parameters, on the basis that for this tip size the gel diffusion time (approximate time constant of the poroelastic (PE) response) is of the order of , so that the PE response is negligible. These parameters are then used to fit the data from a second diameter flat-ended cone for the PE parameters, using the VE parameters extracted from the data from the tip. Data from tests on five different mouse tibial plateaus are presented and fitted. Parameter variation studies for the larger indenter show that for this case the VE and PE time responses overlap in time, necessitating the use of both models.
Skip Nav Destination
e-mail: lewis001@umn.edu
Article navigation
January 2009
Research Papers
Poroviscoelastic Cartilage Properties in the Mouse From Indentation
Sidharth Chiravarambath,
Sidharth Chiravarambath
Department of Orthopaedic Surgery, and Department of Aerospace Engineering and Mechanics,
University of Minnesota
, Minneapolis, MN 55455
Search for other works by this author on:
Narendra K. Simha,
Narendra K. Simha
Department of Orthopaedic Surgery, and Department of Aerospace Engineering and Mechanics,
University of Minnesota
, Minneapolis, MN 55455
Search for other works by this author on:
Ravi Namani,
Ravi Namani
Department of Mechanical, Aerospace, and Structural Engineering,
Washington University
, St. Louis, MO 63102
Search for other works by this author on:
Jack L. Lewis
Jack L. Lewis
Department of Orthopaedic Surgery,
e-mail: lewis001@umn.edu
University of Minnesota
, Minneapolis, MN 55455
Search for other works by this author on:
Sidharth Chiravarambath
Department of Orthopaedic Surgery, and Department of Aerospace Engineering and Mechanics,
University of Minnesota
, Minneapolis, MN 55455
Narendra K. Simha
Department of Orthopaedic Surgery, and Department of Aerospace Engineering and Mechanics,
University of Minnesota
, Minneapolis, MN 55455
Ravi Namani
Department of Mechanical, Aerospace, and Structural Engineering,
Washington University
, St. Louis, MO 63102
Jack L. Lewis
Department of Orthopaedic Surgery,
University of Minnesota
, Minneapolis, MN 55455e-mail: lewis001@umn.edu
J Biomech Eng. Jan 2009, 131(1): 011004 (9 pages)
Published Online: November 18, 2008
Article history
Received:
December 21, 2007
Revised:
June 17, 2008
Published:
November 18, 2008
Citation
Chiravarambath, S., Simha, N. K., Namani, R., and Lewis, J. L. (November 18, 2008). "Poroviscoelastic Cartilage Properties in the Mouse From Indentation." ASME. J Biomech Eng. January 2009; 131(1): 011004. https://doi.org/10.1115/1.3005199
Download citation file:
Get Email Alerts
Evaluation of an Unloading Concept for Knee Osteoarthritis: A Pilot Study in a Small Patient Group
J Biomech Eng (January 2024)
Related Articles
Response to Comment by Charles W. McCutchen
J Biomech Eng (August,2004)
Human Joint Simulation Using LifeMOD Co-Simulation
J. Med. Devices (June,2008)
Related Proceedings Papers
Related Chapters
STRUCTURAL RELIABILITY ASSESSMENT OF PIPELINE GIRTH WELDS USING GAUSSIAN PROCESS REGRESSION
Pipeline Integrity Management Under Geohazard Conditions (PIMG)
Data Tabulations
Structural Shear Joints: Analyses, Properties and Design for Repeat Loading
List of Commercial Codes
Introduction to Finite Element, Boundary Element, and Meshless Methods: With Applications to Heat Transfer and Fluid Flow