Skip Nav Destination
Issues
January 2011
ISSN 0148-0731
EISSN 1528-8951
In this Issue
Research Papers
Engineered Tissue Scaffolds With Variational Porous Architecture
J Biomech Eng. January 2011, 133(1): 011001.
doi: https://doi.org/10.1115/1.4002933
Topics:
Porosity
,
Tissue scaffolds
Patient-Specific Modeling of Corneal Refractive Surgery Outcomes and Inverse Estimation of Elastic Property Changes
J Biomech Eng. January 2011, 133(1): 011002.
doi: https://doi.org/10.1115/1.4002934
Topics:
Ablation (Vaporization technology)
,
Cornea
,
Elasticity
,
Finite element model
,
Surgery
,
Performance
,
Lasers
Computational Fluid Dynamics Simulations of Particle Deposition in Large-Scale, Multigenerational Lung Models
J Biomech Eng. January 2011, 133(1): 011003.
doi: https://doi.org/10.1115/1.4002936
Volumetric Stress-Strain Analysis of Optohydrodynamically Suspended Biological Cells
J Biomech Eng. January 2011, 133(1): 011004.
doi: https://doi.org/10.1115/1.4002939
Topics:
Biological cells
,
Biomechanics
,
Stress
,
Microfluidics
,
Flow (Dynamics)
Deformations and End Effects in Isolated Blood Vessel Testing
J Biomech Eng. January 2011, 133(1): 011005.
doi: https://doi.org/10.1115/1.4002935
Topics:
Blood vessels
,
Deformation
,
Needles
,
Pressure
,
Testing
,
Vessels
,
Geometry
,
Fibers
,
Simulation
,
Materials properties
The Effect of Kinematic and Kinetic Changes on Meniscal Strains During Gait
J Biomech Eng. January 2011, 133(1): 011006.
doi: https://doi.org/10.1115/1.4003008
Topics:
Kinematics
,
Knee
,
Rotation
,
Stress
,
Finite element model
,
Damage
,
Osteoarthritis
,
Cycles
Axisymmetric Optical-Trap Measurement of Red Blood Cell Membrane Elasticity
J Biomech Eng. January 2011, 133(1): 011007.
doi: https://doi.org/10.1115/1.4003127
Topics:
Deformation
,
Elasticity
,
Erythrocytes
,
Membranes
,
Shapes
,
Equilibrium (Physics)
,
Glass
Simulation of a Chain of Collapsible Contracting Lymphangions With Progressive Valve Closure
J Biomech Eng. January 2011, 133(1): 011008.
doi: https://doi.org/10.1115/1.4002799
Cartilage Thickness Distribution Affects Computational Model Predictions of Cervical Spine Facet Contact Parameters
J Biomech Eng. January 2011, 133(1): 011009.
doi: https://doi.org/10.1115/1.4002855
Topics:
Cartilage
,
Cervical spine
,
Pressure
,
Physiology
,
Geometry
,
Stress
,
Kinematics
,
Finite element analysis
The Role of Mass Balance Equations in Growth Mechanics Illustrated in Surface and Volume Dissolutions
J Biomech Eng. January 2011, 133(1): 011010.
doi: https://doi.org/10.1115/1.4003133
Topics:
Biological tissues
,
Deformation
,
Density
,
Modeling
,
Traction
,
Biomechanics
,
Constitutive equations
,
Biochemistry
,
Biophysics
,
Molecular biophysics
Intrasac Pressure Changes and Vascular Remodeling After Endovascular Repair of Abdominal Aortic Aneurysms: Review and Biomechanical Model Simulation
J Biomech Eng. January 2011, 133(1): 011011.
doi: https://doi.org/10.1115/1.4003134
Topics:
Aneurysms
,
Pressure
,
Simulation
,
Biomechanics
,
Maintenance
,
Stress
Pure Passive Hyperextension of the Human Cadaver Knee Generates Simultaneous Bicruciate Ligament Rupture
J Biomech Eng. January 2011, 133(1): 011012.
doi: https://doi.org/10.1115/1.4003135
Technical Briefs
Biomechanical Measurements of Torsion-Tension Coupling in Human Cadaveric Femurs
J Biomech Eng. January 2011, 133(1): 014501.
doi: https://doi.org/10.1115/1.4002937
Topics:
Tension
,
Torsion
,
Rotation
,
Biomechanics
Comparison of MRI-Based Estimates of Articular Cartilage Contact Area in the Tibiofemoral Joint
J Biomech Eng. January 2011, 133(1): 014502.
doi: https://doi.org/10.1115/1.4002938
Topics:
Cartilage
,
Knee
,
Magnetic resonance imaging
,
Reliability
,
Stress
Numerical Modeling of Stress in Stenotic Arteries With Microcalcifications: A Parameter Sensitivity Study
J Biomech Eng. January 2011, 133(1): 014503.
doi: https://doi.org/10.1115/1.4003128
Topics:
Finite element analysis
,
Hoop stress
,
Stress
,
Computer simulation
,
Simulation
Experimental Validation of a Finite Element Model of the Proximal Femur Using Digital Image Correlation and a Composite Bone Model
J Biomech Eng. January 2011, 133(1): 014504.
doi: https://doi.org/10.1115/1.4003129
Email alerts
RSS Feeds
A Multichamber Pulsating-Flow Device With Optimized Spatial Shear Stress and Pressure for Endothelial Cell Testing
J Biomech Eng (January 2025)