A challenging problem on observer-based, integrated fault diagnosis and fault-tolerant control for linear systems subject to actuator faults and control input constraints is studied in this paper. An adaptive observer approach is used for the joint state-fault magnitude estimation, and a feedback controller is designed to stabilize the closed-loop system without violating the actuator limits in the presence of actuator faults. Matrix inequality conditions are provided for computation of design parameters of the observer and the feedback controller, and the admissible initial conditions and estimation errors are bounded by invariant ellipsoidal sets. The design results are closely related to the fault magnitude and variation rate, and a necessary condition on the admissible fault magnitudes dependent on the control limits is directly obtained from the design process. The proposed design framework allows a direct application of the pole placement method to obtain stabilization results. To improve the system performance, a nonlinear programming-based optimization algorithm is proposed to compute an optimized feedback gain, whereas the one obtained by pole placement can be taken as an initial feasible solution for nonlinear optimization. Numerical studies with two flight control systems demonstrate the effectiveness of proposed design techniques.
Skip Nav Destination
Article navigation
July 2013
Research-Article
Adaptive Observer-Based Integrated Fault Diagnosis and Fault-Tolerant Control Systems Against Actuator Faults and Saturation
Jinhua Fan,
Jinhua Fan
College of Mechatronic Engineering and Automation,
Department of Mechanical and Industrial Engineering,
Montreal, QC H3G 1M8, Canada
e-mail: fjhcom@gmail.com
National University of Defense Technology
,Changsha, Hunan, 410073
PRC
;Department of Mechanical and Industrial Engineering,
Concordia University
,Montreal, QC H3G 1M8, Canada
e-mail: fjhcom@gmail.com
Search for other works by this author on:
Youmin Zhang,
Youmin Zhang
1
Department of Mechanical and Industrial Engineering,
e-mail: ymzhang@encs.concordia.ca
Concordia University
,Montreal, QC H3G 1M8
, Canada
e-mail: ymzhang@encs.concordia.ca
1Corresponding author.
Search for other works by this author on:
Zhiqiang Zheng
Zhiqiang Zheng
College of Mechatronic Engineering and Automation,
e-mail: zqzheng@nudt.edu.cn
National University of Defense Technology
,Changsha, Hunan, 410073
PRC
e-mail: zqzheng@nudt.edu.cn
Search for other works by this author on:
Jinhua Fan
College of Mechatronic Engineering and Automation,
Department of Mechanical and Industrial Engineering,
Montreal, QC H3G 1M8, Canada
e-mail: fjhcom@gmail.com
National University of Defense Technology
,Changsha, Hunan, 410073
PRC
;Department of Mechanical and Industrial Engineering,
Concordia University
,Montreal, QC H3G 1M8, Canada
e-mail: fjhcom@gmail.com
Youmin Zhang
Department of Mechanical and Industrial Engineering,
e-mail: ymzhang@encs.concordia.ca
Concordia University
,Montreal, QC H3G 1M8
, Canada
e-mail: ymzhang@encs.concordia.ca
Zhiqiang Zheng
College of Mechatronic Engineering and Automation,
e-mail: zqzheng@nudt.edu.cn
National University of Defense Technology
,Changsha, Hunan, 410073
PRC
e-mail: zqzheng@nudt.edu.cn
1Corresponding author.
Contributed by the Dynamic Systems Division of ASME for publication in the JOURNAL OF DYNAMIC SYSTEMS, MEASUREMENT, AND CONTROL. Manuscript received February 20, 2012; final manuscript received December 25, 2012; published online May 13, 2013. Assoc. Editor: Won-jong Kim.
J. Dyn. Sys., Meas., Control. Jul 2013, 135(4): 041008 (13 pages)
Published Online: May 13, 2013
Article history
Received:
February 20, 2012
Revision Received:
December 25, 2012
Citation
Fan, J., Zhang, Y., and Zheng, Z. (May 13, 2013). "Adaptive Observer-Based Integrated Fault Diagnosis and Fault-Tolerant Control Systems Against Actuator Faults and Saturation." ASME. J. Dyn. Sys., Meas., Control. July 2013; 135(4): 041008. https://doi.org/10.1115/1.4023763
Download citation file:
Get Email Alerts
Hybrid Kinematic-dynamic Sideslip and Friction Estimation
J. Dyn. Sys., Meas., Control
Koopman Model Predictive Control of an Integrated Thermal Management System for Electric Vehicles
J. Dyn. Sys., Meas., Control
Electromagnetic Model of Linear Resonant Actuators
J. Dyn. Sys., Meas., Control (May 2023)
Discrete Robust Control of Robot Manipulators Using an Uncertainty and Disturbance Estimator
J. Dyn. Sys., Meas., Control (May 2023)
Related Articles
Adaptive Observer for Fault Diagnosis in Nonlinear Discrete-Time Systems
J. Dyn. Sys., Meas., Control (March,2008)
Robust Unknown Input Observer for Nonlinear Systems and Its Application to Fault Detection and Isolation
J. Dyn. Sys., Meas., Control (July,2008)
Nonlinear Fault Diagnosis of Jet Engines by Using a Multiple Model-Based Approach
J. Eng. Gas Turbines Power (January,2012)
Gray-Box Approach for Fault Detection of Dynamical Systems
J. Dyn. Sys., Meas., Control (September,2003)
Related Proceedings Papers
Related Chapters
Unit Concurrent Fault Diagnosis Based on Artificial Immune System and Evidence Theory Design of Unit Fault Diagnosis System Software
Proceedings of the International Conference on Technology Management and Innovation
Design of Fault Diagnosis System of Industrial Boiler Based on MATLAB
International Conference on Instrumentation, Measurement, Circuits and Systems (ICIMCS 2011)
Fault Diagnosis based on Rough Set and Dependent Feature Vector for Rolling Element Bearings
International Conference on Control Engineering and Mechanical Design (CEMD 2017)