1-20 of 27
Keywords: scanning electron microscopy
Close
Follow your search
Access your saved searches in your account

Would you like to receive an alert when new items match your search?
Close Modal
Sort by
Journal Articles
Publisher: ASME
Article Type: Research Papers
J. Electrochem. En. Conv. Stor. December 2011, 8(6): 061014.
Published Online: September 27, 2011
... of the samples are, Sample # 1 = 0.05 mol/liter for SDC and 0.1 m/200 ml for Na 2 CO 3 09 01 2011 13 03 2011 23 06 2011 27 09 2011 27 09 2011 biofuel catalysts electrochemical electrodes organic compounds scanning electron microscopy solid oxide fuel cells X-ray...
Journal Articles
Publisher: ASME
Article Type: Research Papers
J. Electrochem. En. Conv. Stor. December 2011, 8(6): 061003.
Published Online: September 23, 2011
... density performance in fuel cell studies. 20 07 2009 30 06 2011 23 09 2011 23 09 2011 catalysts crystal microstructure electrochemical electrodes electrolytes heat treatment hydrophobicity mass transfer proton exchange membrane fuel cells scanning electron microscopy...
Journal Articles
Journal Articles
Publisher: ASME
Article Type: Research Papers
J. Electrochem. En. Conv. Stor. August 2011, 8(4): 041012.
Published Online: April 1, 2011
... conductivity nanocomposites nanofabrication particle size scanning electron microscopy solid oxide fuel cells thermal stability X-ray diffraction yttrium compounds 14 10 2010 24 11 2010 01 04 2011 01 04 2011 2011 American Society of Mechanical Engineers ...
Journal Articles
Publisher: ASME
Article Type: Research Papers
J. Electrochem. En. Conv. Stor. August 2011, 8(4): 041013.
Published Online: April 1, 2011
... was prepared by coprecipitation method. Ni based electrode was used to fabricate the cell by dry pressing technique. The crystal structure and surface morphology were characterized by an X-ray diffractometer, scanning electron microscopy (SEM), and high resolution transmission electron microscopy (TEM...
Journal Articles
Publisher: ASME
Article Type: Research Papers
J. Electrochem. En. Conv. Stor. February 2011, 8(1): 011007.
Published Online: November 3, 2010
... into a single cubic phase. Because no significant densification of the Co-doped ScSZ samples was observed before and after the phase change and Co diffusion, it suggests that these reaction sintering processes should not be strongly related to densification. From the results of scanning electron microscopy, Co...
Journal Articles
Publisher: ASME
Article Type: Technical Briefs
J. Electrochem. En. Conv. Stor. February 2011, 8(1): 014501.
Published Online: September 30, 2010
... ). This new composite membrane showed higher water uptake (12.7%) than that of normal hydrophobic ePTFE based composite membrane (6.3%) and better proton conductivity. Scanning electron microscopy micrographs showed that the hydrophilic ePTFE based membrane can easily form a dense composite membrane while...
Journal Articles
Publisher: ASME
Article Type: Research Papers
J. Electrochem. En. Conv. Stor. August 2010, 7(4): 041009.
Published Online: April 7, 2010
... scanning electron microscopy (FESEM) was conducted to provide visual documentation of leaking failure sites. The analysis of the experimental leaking data indicates that the MEA has much shorter lifetimes at the same nominal stress levels than membrane samples without the electrode layers. FESEM...
Journal Articles
Publisher: ASME
Article Type: Research Papers
J. Electrochem. En. Conv. Stor. June 2010, 7(3): 031011.
Published Online: March 12, 2010
... performance for methanol oxidation at 80 ° C . The effect of temperature and time for thermal decomposition was optimized with respect to methanol oxidation, and the catalysts were characterized by cyclic voltammetry, linear sweep voltammetry, scanning electron microscopy, X-ray diffraction studies, and X-ray...
Journal Articles
Journal Articles
Journal Articles
Publisher: ASME
Article Type: Special Section On The 2Nd European Fuel Cell Technology And Applications Conference
J. Electrochem. En. Conv. Stor. May 2009, 6(2): 021305.
Published Online: March 3, 2009
... and 0.6 mg Pt cm − 2 on the anode and cathode, respectively. Scanning electron microscopy analysis was used to investigate the electrodes’ morphology. The performance of the MEAs was measured by polarization curves. It was observed that the sieve printing technique is highly reproducible and significantly...
Journal Articles
Publisher: ASME
Article Type: Research Papers
J. Electrochem. En. Conv. Stor. May 2009, 6(2): 021007.
Published Online: February 24, 2009
.... DKKK powders have been manufactured using a wet coprecipitation chemical route, and Praxair powders have been produced by spray pyrolysis. The morphology of the powders, as studied by scanning electron microscopy, has been very different. DKKK powders were presented as soft ( ∼ 100 μ m ) spherical...
Journal Articles
Publisher: ASME
Article Type: Research Papers
J. Electrochem. En. Conv. Stor. February 2009, 6(1): 011018.
Published Online: November 12, 2008
... on each alloy were identified using X-ray diffraction, scanning electron microscopy, and energy dispersive X-ray spectroscopy. Thin surface scales were formed that included Cr-, Fe-, Al-, and Si-oxides as well as Mn–Cr spinel. The surface composition estimated from the analytical data is used...
Journal Articles
Publisher: ASME
Article Type: First China-Japan Workshop On Solid Oxide Fuel Cells
J. Electrochem. En. Conv. Stor. August 2008, 5(3): 031206.
Published Online: May 23, 2008
... layer on it, which was favorable in reducing both electrolyte and polarization resistances. 10 09 2007 15 10 2007 23 05 2008 anodes electrochemical electrodes electrokinetic effects electrolytes nickel scanning electron microscopy solid oxide fuel cells yttrium compounds...
Journal Articles
Publisher: ASME
Article Type: Research Papers
J. Electrochem. En. Conv. Stor. August 2008, 5(3): 031008.
Published Online: May 23, 2008
... and a film of controlled porosity was generated. The morphology of the GDL porous structure was then analyzed by scanning electron microscopy. GDL porosity characterization was done by both Brunauer–Emmett–Teller (BET) and mercury-intrusion porosimeter. The effects of PS concentration and extraction time...
Journal Articles
Publisher: ASME
Article Type: Research Papers
J. Electrochem. En. Conv. Stor. February 2008, 5(1): 011001.
Published Online: January 16, 2008
... by scanning electron microscopy and energy dispersive X-ray spectroscopy line-scan analysis for exposure at high temperature. The variation with time of the area-specific resistance at 800°C has been recorded up to 1000 h . The evaporation rate of Cr-containing species has been also evaluated by a qualitative...
Journal Articles
Publisher: ASME
Article Type: Research Papers
J. Electrochem. En. Conv. Stor. February 2008, 5(1): 011003.
Published Online: January 16, 2008
... ) confirms a cubic structure with unit cell parameter of 8.424 Å . Scanning electron microscopy images reveal a dense electrolyte structure. Thermal analysis (TGA/DTA) was also conducted on the material to determine possible endothermic and exothermic peaks and phase transformations. Raman spectroscopy data...
Journal Articles
Publisher: ASME
Article Type: Technical Papers
J. Electrochem. En. Conv. Stor. February 2007, 4(1): 88–98.
Published Online: April 17, 2006
... containing varying weight percentages (1, 2, 3, 5, 7.5, and 10 wt. % ) of alkali hydroxides (NaOH, KOH, and LiOH) were evaluated at 25 ° C . The precipitates formed in supersaturated solutions were characterized by x-ray diffraction and scanning electron microscopy. Results: All Na B O 2 physicochemical...
Journal Articles
Publisher: ASME
Article Type: Design Innovations
J. Electrochem. En. Conv. Stor. November 2007, 4(4): 520–524.
Published Online: April 17, 2006
... of support PEM tube were characterized intensively by scanning electron microscopy observation. In addition, the conductivity and impermeability were measured by electrochemical impedance spectroscopy (EIS) and the bubble method, respectively. Results show that the conductivity of the PEM can reach as low...