Abstract
Chromatographic techniques are basic tools in systematic toxicological analysis. Extensive data bases with retention parameters of known drugs to aid in the identification of substances found are available or in preparation. For a search in such a data base the computer is indispensable. The commonly used window search has some disadvantages which can be overcome by a search based on the statistical concept, the mean list length. The latter retrieval system gives for each candidate in the identification process a probability value. It is shown that these probability values are highly influenced by the reproducibility of the retention parameters of the analytical systems used. Explanations for these phenomena are given.
References
1.
Akkerboom
, J. C.
, Schepers
, P.
, and Werff
, J. van de
, “Thin Layer Chromatography, a Case Study
,” Statistica Neerlandica
, Vol. 34
, No. 4
, 1980
, pp. 173
-187
.2.
Schepers
, P.
, Franke
, J. P.
, and Zeeuw
, R. A. de
, “System Evaluation and Substance Identification in Systematic Toxicological Analysis by the Mean List Length Approach
,” Journal of Analytical Toxicology
0146-4760, Vol. 7
, No. 6
, Nov./Dec. 1983, pp. 272
-278
.3.
Finkle
, B. S.
, Franke
, J. P.
, Moffat
, A. C.
, Moeller
, M.
, Mueller
, R. K.
, and Zeeuw
, R. A. de
, “Gaschromatografische Retentionsindices toxikologisch relevanter Verbindungen auf SE-30 oder OV-1
,” Mitteilung I der Kommission für klinisch-toxikologische Analytik der Deutsche Forschungsgemeinschaft
, Verlag Chemie, Weinheim
, Deerfield Beach, FL, Basel
, 1982
.4.
Stead
, A. H.
, Gill
, R.
, Wright
, T.
, Gibbs
, J. P.
, and Moffat
, A. C.
, “Standardized Thin Layer Chromatographic Systems for the Identification of Drugs and Poisons a Review
,” Analyst
, Vol. 107
, No. 1279
, 1982
, pp. 1106
-1168
.5.
Ardrey
, R. E.
and Moffat
, A. C.
, “Gas Liquid Chromatographic Retention Indices of 1318 Substances of Toxicological Interest on SE-30 or OV-1 Stationary Phase
,” Journal Chromatography
, Vol. 220
, No. 3
, 1981
;Ardrey
, R. E.
and Moffat
, A. C.
, “Gas Liquid Chromatographic Retention Indices of 1318 Substances of Toxicological Interest on SE-30 or OV-1 Stationary Phase
,” Chromatographic Review
, Vol. 25
, No. 3
, pp. 195
-252
.
This content is only available via PDF.
All rights reserved. This material may not be reproduced or copied, in whole or in part, in any printed, mechanical, electronic, film, or other distribution and storage media, without the written consent of ASTM International.
You do not currently have access to this content.