Abstract

Fires caused by electrical shorting are difficult to identify with certainty from fire pattern analysis alone. Surface analysis techniques, such as electron spectroscopy for chemical analysis (ESCA) and auger electron spectroscopy (AES), can be used to determine the history of an electrical short circuit by characterizing the environment in which the electrical arc residues were formed. In a fire that destroys insulation, the surface of the arc bead formed from the resultant electrical short circuit would show the presence of combustion products. If the electrical short circuit occurred before the fire had started, then arc bead analysis would show the absence of combustion products.

References

1.
Sieverts
,
A.
and
Krumbhaar
,
W.
,
Berichte der Deutschen Chemischen Gesellschaft
, Vol.
43
,
1910
,
and
Zeitschrift fuer Physik und Chemie
, Vol.
75
.
2.
Fast
,
J. D.
,
Interaction of Metals and Gases
.
Academic Press
,
New York
,
1965
.
This content is only available via PDF.
You do not currently have access to this content.