Abstract

Solid-phase extraction (SPE) by means of disposable columns has become a widely accepted technique for sample pretreatment in toxicology, both for directed analyses and for screening analyses. However, the sample capacity in SPE is usually limited to a few millilitres.

Therefore, we have investigated to what extent these problems can be overcome by using Empore extraction disks, consisting of chemically modified C-8 reversed-phase silica, embedded in an inert polytetrafluoroethylene (PTFE) matrix. Human urine was selected as the matrix and dexetimide and mepyramine were initially used as test drugs because these drugs were available in tritiated form. Additional drugs investigated included codeine, hexobarbital, imipramine, methamphetamine, and nitrazepam.

In these investigations, the sample capacity for untreated urine was at least 25 mL, and analyte quantities up to 250 μg could be retained by these filters. Washing with water/methanol mixtures was successful in removing substantial amounts of endogenous interferences, and methanol proved to be an acceptable eluent. Thus, these disks seem to have interesting potential for toxicological analysis in that sample concentration and cleanup can be achieved at the same time.

References

1.
McDowall
,
R. D.
,
Pearce
,
J. C.
, and
Murkitt
,
G. S.
, “
Liquid-Solid Sample Preparation in Drug Analysis
,”
Journal of Pharmaceutical and Biomedical Analysis
 0731-7085, Vol.
4
, No.
1
,
01
1986
, pp.
3
-
21
.
2.
Johnson
,
E. L.
,
Johnson
,
E. L.
,
Reynolds
,
D. L.
,
Wright
,
D. S.
, and
Pachlan
,
L. A.
, “
Biological Sample Preparation
,”
Journal of Chromatographic Science
 0021-9665, Vol.
26
,
1988
, pp.
372
-
379
.
3.
Chen
,
X.
,
Wijsbeek
,
J.
,
van Veen
,
J.
,
Franke
,
J. P.
, and
de Zeeuw
,
R. A.
, “
Solid-Phase Extraction for the Screening of Acidic, Neutral and Basic Drugs in Plasma Using a Single-Column Procedure on Bond Elut Certify
,”
Journal of Chromatography: Biomedical Applications
, Vol.
529
, No.
1
,
1990
, pp.
161
-
166
.
4.
Moffat
,
A. C.
,
Jackson
,
J. V.
,
Moss
,
M. S.
, and
Widdop
,
B.
in
Isolation and Identification of Drugs
, 2nd ed.,
E. C.
Clarke
, Ed.,
Pharmaceutical Press
,
London
,
1986
.
5.
McDowall
,
R. D.
, “
Sample Preparation for Biomedical Analysis
,”
Journal of Chromatography
 0021-9673, Vol.
492
, No.
3
,
1989
, pp.
3
-
58
.
6.
New Empore Extraction Disks for Environmental Analysis
,”
Analytichem International
,
Harbor City, CA
,
1989
.
7.
Brouwer
,
E. R.
,
Lingeman
,
H.
, and
Brinkman
,
U. A. T.
, “
Use of Membrane Extraction Disks for On-Line Trace Enrichment of Organic Compounds from Aqueous Samples
,”
Chromatographia
 0009-5893, Vol.
29
, No.
9/10
,
05
1990
, pp.
415
-
418
.
This content is only available via PDF.
You do not currently have access to this content.