The key product of a combined cycle power plant is electric power generated for industrial, commercial, and residential customers. In that sense, the key performance metric that establishes the pecking order among thousands of existing, new, old, and planned power plants is the thermal efficiency. This is a ratio of net electric power generated by the plant to its rate of fuel consumption in the gas turbine combustors and, if applicable, heat recovery boiler duct burners. The term in the numerator of that simple ratio is subject to myriad ambiguities and/or misunderstandings resulting primarily from the lack of a standardized definition agreed upon by all major players. More precisely, it is the lack of a standardized definition of the plant auxiliary power consumption (or load) that must be subtracted from the generator output of all turbines in the plant, which then determines the net contribution of that power plant to the electric grid. For a combined cycle power plant, the key contributor to the plant’s auxiliary power load is the heat rejection system. In particular, any statement of combined cycle power plant thermal efficiency that does not specify the steam turbine exhaust pressure and the exhaust steam cooling system to achieve that pressure at the site ambient and loading conditions is subject to conjecture. Furthermore, for an assessment of the realism associated with the two in terms of economic and mechanical design feasibility, it is necessary to know the steam turbine exhaust end size and configuration. Using fundamental design principles, this paper provides a precise definition of the plant auxiliary load and quantifies its ramification on the plant’s net thermal efficiency. In addition, four standard auxiliary load levels are quantitatively defined based on a rigorous study of heat rejection system design considerations with a second-law perspective.
Skip Nav Destination
Article navigation
April 2011
Research Papers
Importance of Auxiliary Power Consumption for Combined Cycle Performance
S. Can Gülen
S. Can Gülen
Principal Engineer
Search for other works by this author on:
S. Can Gülen
Principal Engineer
J. Eng. Gas Turbines Power. Apr 2011, 133(4): 041801 (10 pages)
Published Online: November 18, 2010
Article history
Received:
May 12, 2010
Revised:
May 26, 2010
Online:
November 18, 2010
Published:
November 18, 2010
Citation
Gülen, S. C. (November 18, 2010). "Importance of Auxiliary Power Consumption for Combined Cycle Performance." ASME. J. Eng. Gas Turbines Power. April 2011; 133(4): 041801. https://doi.org/10.1115/1.4002254
Download citation file:
Get Email Alerts
Cited By
Heat Release Characteristics of a Volatile, Oxygenated, and Reactive Fuel in a Direct Injection Engine
J. Eng. Gas Turbines Power
Comprehensive Life Cycle Analysis of Diverse Hydrogen Production Routes and Application on a Hydrogen Engine
J. Eng. Gas Turbines Power
Related Articles
Modeling the Performance Characteristics of Diesel Engine Based Combined-Cycle Power Plants—Part II: Results and Applications
J. Eng. Gas Turbines Power (January,2004)
Second Law Efficiency of the Rankine Bottoming Cycle of a Combined Cycle Power Plant
J. Eng. Gas Turbines Power (January,2010)
Application of “H Gas Turbine” Design Technology to Increase Thermal Efficiency and Output Capability of the Mitsubishi M701G2 Gas Turbine
J. Eng. Gas Turbines Power (April,2005)
A Computational Model of a Combined Cycle Power Generation Unit
J. Energy Resour. Technol (September,2004)
Related Proceedings Papers
Related Chapters
Combined Cycle Power Plant
Energy and Power Generation Handbook: Established and Emerging Technologies
Introduction
Consensus on Operating Practices for Control of Water and Steam Chemistry in Combined Cycle and Cogeneration
Lay-Up and Start-Up Practices
Consensus on Operating Practices for Control of Water and Steam Chemistry in Combined Cycle and Cogeneration