Electrohydrodynamically (EHD) enhanced flow boiling of refrigerant R-134a inside grooved channels of approximately 1-mm hydraulic diameter was investigated with the objective of addressing the applicability of the EHD technique in highly compact heat exchangers. Two sets of experiments were performed. The first set included experiments in a channel with a smooth heat transfer wall, whereas in the second set a corrugated (enhanced) surface was used. In each case experiments were conducted as a function of the applied electrical field strength, electric field polarity, flow Reynolds number, inlet test section vapor quality, and flow direction (upward, downward, or horizontal). It is demonstrated that in all cases the EHD effect can substantially increase the heat transfer coefficient particularly at low Reynolds numbers and when applied over the enhanced heat transfer wall.
Skip Nav Destination
e-mail: ohadi@eng.umd.edu
Article navigation
Research Papers
EHD Enhanced Convective Boiling of R-134a in Grooved Channels—Application to Subcompact Heat Exchangers
M. Salehi,
M. Salehi
Heat Transfer Enhancement Laboratory, Center for Environmental Energy Engineering, Department of Mechanical Engineering, University of Maryland, College Park, MD 20742
Search for other works by this author on:
M. M. Ohadi,
M. M. Ohadi
Heat Transfer Enhancement Laboratory, Center for Environmental Energy Engineering, Department of Mechanical Engineering, University of Maryland, College Park, MD 20742
e-mail: ohadi@eng.umd.edu
Search for other works by this author on:
S. Dessiatoun
S. Dessiatoun
Heat Transfer Enhancement Laboratory, Center for Environmental Energy Engineering, Department of Mechanical Engineering, University of Maryland, College Park, MD 20742
Search for other works by this author on:
M. Salehi
Heat Transfer Enhancement Laboratory, Center for Environmental Energy Engineering, Department of Mechanical Engineering, University of Maryland, College Park, MD 20742
M. M. Ohadi
Heat Transfer Enhancement Laboratory, Center for Environmental Energy Engineering, Department of Mechanical Engineering, University of Maryland, College Park, MD 20742
e-mail: ohadi@eng.umd.edu
S. Dessiatoun
Heat Transfer Enhancement Laboratory, Center for Environmental Energy Engineering, Department of Mechanical Engineering, University of Maryland, College Park, MD 20742
J. Heat Transfer. Nov 1997, 119(4): 805-809 (5 pages)
Published Online: November 1, 1997
Article history
Received:
March 25, 1996
Revised:
July 15, 1997
Online:
December 5, 2007
Citation
Salehi, M., Ohadi, M. M., and Dessiatoun, S. (November 1, 1997). "EHD Enhanced Convective Boiling of R-134a in Grooved Channels—Application to Subcompact Heat Exchangers." ASME. J. Heat Transfer. November 1997; 119(4): 805–809. https://doi.org/10.1115/1.2824186
Download citation file:
Get Email Alerts
Cited By
Related Articles
Impact of Channel Geometry on Two-Phase Flow Heat Transfer Characteristics of Refrigerants in Microchannel Heat Exchangers
J. Heat Transfer (May,1998)
EHD-Enhanced Boiling of R-123 Over Commercially Available Enhanced Tubes
J. Heat Transfer (November,1995)
Effect of Channel Blockage on Critical Heat Flux for a Horizontal Cylinder in Crossflow
J. Heat Transfer (November,1995)
Film Boiling Incipience at the Departure From Natural Convection on Flat, Smooth Surfaces
J. Heat Transfer (May,1998)
Related Proceedings Papers
Related Chapters
Flow Boiling
Thermal Management of Microelectronic Equipment
Comparison of the Availability of Trip Systems for Reactors with Exothermal Reactions (PSAM-0361)
Proceedings of the Eighth International Conference on Probabilistic Safety Assessment & Management (PSAM)
Flow Boiling
Thermal Management of Microelectronic Equipment, Second Edition