As a minimally invasive means of extracting a tissue sample from a patient, current endoscopic biopsy needles generally do not preserve tissue histology and often require multiple attempts to obtain a tissue sample. This paper presents an endoscopic biopsy needle with internal flexures that enables tissue to enter the hollow needle and then be severed from the surrounding tissue when the needle is withdrawn. Using force-deflection and sample weight data from 10× scaled prototypes, variations of a flexural design captured 1.1grams of a tissue phantom on average, as compared to wedge-type designs that averaged 0.7-0.8grams. Sample mass exhibited an increase in mass as the feature angle decreased. Peak entrance forces (P2) for the flexure design were lower than for both wedge and extended wedge designs, and resistance forces (S2) were higher upon needle extraction. A low-angle (15 and 30deg) feature also produced a lower entrance friction (S1) and higher exit resistance (S2) compared with 45 and 60deg features. These results suggest that a biopsy needle with 15deg flexures could increase sample length and mass as well as sampling success rates for core biopsy procedures. Future tests of the flexural biopsy needle design will use this information to determine dimensions for laser cut features of 1× scale needles.

1.
Pohl
,
H.
, and
Welch
,
H. G.
, 2005, “
The Role of Overdiagnosis and Reclassification in the Marked Increase of Esophageal Adenocarcinoma Incidence
.”
J. Natl. Cancer Inst.
0027-8874,
97
(
2
), pp.
142
146
.
2.
National Center for Health Statistics
, 1998, “
Ambulatory and Inpatient Procedures in the United States, 1996
,”
Vital and Health Statistics
, Series 13, No. 139.
4.
Brugge
,
W. R.
, 2004, personal communication.
6.
Okamura
,
A. M.
,
Simone
,
C.
, and
O'Leary
,
M. D.
, 2004, “
Force Modeling for Needle Insertion Into Soft Tissue
,”
IEEE Trans. Biomed. Eng.
0018-9294,
51
(
10
), p.
1714
.
7.
Bravo
,
A. A.
,
Sheth
,
S. G.
, and
Chopra
,
S.
, 2001, “
Liver Biopsy
,”
N. Engl. J. Med.
0028-4793,
344
, pp.
495
500
.
8.
Figueredo
,
S.
, 2006, Design of an Endoscopic Biopsy Needle With Flexural Members, SM thesis, MIT.
9.
Avallone
,
E. A.
, and
Baumeister
,
T.
, III
, 1996,
Marks’ Standard Handbook for Mechanical Engineers
, 10th ed.,
McGraw-Hill
,
New York
, pp.
5
23
.
10.
Antony
,
J.
, 2003,
Design of Experiments for Engineers and Scientists
,
Butterworth-Heinemann
,
Oxford
.
11.
Mostovoy
,
G.
, 2005, personal communication.
12.
Leiner
,
P. B.
, “
Physical and Chemical Properties of Gelatin
,” www.gelatin.comwww.gelatin.com.
13.
Erpelding
,
T. N.
,
Booi
,
R. C.
,
Hollman
,
K. W.
, and
O’Donnell
,
M.
, 2003, “
Measuring Tissue Elastic Properties Using Acoustic Radiation Force on Laser-Generated Bubbles
,” IEEE Ultrasonics Symposium.
14.
Yamada
,
H.
, 1970,
Strength of Biological Materials
,
Williams and Wilkins
,
Baltimore
.
15.
Chanthasopeephan
,
T.
,
Desai
,
J.
, and
Lau
,
A.
, 2003, “
Measuring Forces in Liver Cutting: New Equipment and Experimental Results
.”
Ann. Biomed. Eng.
0090-6964,
31
, pp.
1372
1382
.
16.
Chui
,
C.
,
Kobayashi
,
E.
,
Chen
,
X.
,
Hisada
,
T.
, and
Sakuma
,
I.
, 2004, “
Combined Compression and Elongation Experiments and Nonlinear Modeling of Liver Tissue for Surgical Simulation
.”
Med. Biol. Eng. Comput.
0140-0118,
42
, pp.
787
798
.
17.
Johnson
,
K. L.
, 1985,
Contact Mechanics
,
Cambridge University Press
,
Cambridge
.
19.
Leiner
,
P. B.
, “
Preparing Gelatin Solutions
,” www.gelatin.comwww.gelatin.com.
20.
Simone
,
C.
, and
Okamura
,
A. M.
, 2002, “
Modeling of Needle Insertion Forces for Robot-Assisted Percutaneous Therapy
,”
IEEE International Conference on Robotics Automation
, pp.
2085
2091
.
You do not currently have access to this content.