Advances in medical technology rely heavily on the collection and analysis of measured data to facilitate patient diagnosis and business decisions. The healthcare industry, particularly pharmaceuticals and diagnostic processes, has an ongoing need to improve item tracking and data collection to improve the quality of care while reducing cost. The remote, non-invasive characteristics of radio frequency identification (RFID) can facilitate the information needs of healthcare without imposing additional burden onto the patient or the staff. Properly deployed RFID enabled devices can provide convenient and accurate data for disease diagnosis, evaluation of prescription noncompliance, and identification of medication dosage errors. This paper describes an overview of the concept of an all-encompassing RFID pharmaceutical tracking system that begins with compliance documentation from the drug manufacturer and continues through the confirmation of patient compliance by capsule extraction from the bottle into a pill case and ultimately ingested or inserted into the body. This system also facilitates compliance with Food and Drug Administration proposed e-pedigree requirements and provides data for healthcare decision making. An introduction to healthcare trends is provided in order to communicate the need for such a biocompatible RFID pharmaceutical tracking system. Also presented in this paper is the overall scope of research and in vitro test method to develop biocompatible RFID tag components for use in a “pharmaceutical supply chain system” beginning with the manufacturer, continuing through distribution, and ending at the point of interest within the patient’s body.

1.
World Health Organization
, 2005, “
Preventing Chronic Diseases: A Vital Investment
,” WHO, Geneva, http://www.who.int/chp/chronic_disease_report/full_report.pdfhttp://www.who.int/chp/chronic_disease_report/full_report.pdf, p. 22.
2.
Adeyi
,
O.
,
Smith
,
O.
, and
Robles
,
S.
, 2007,
Public Policy and the Challenge of Chronic Noncommunicable Diseases
,
World Bank
,
Washington, DC
.
3.
Gordis
,
L.
, 2004,
Epidemiology
, 3rd ed.,
Saunders Elsevier
,
Philadelphia, PA
.
4.
Daar
,
A. S.
,
Singer
,
P. A.
,
Persad
,
D. L.
,
Pramming
,
S. K.
,
Matthews
,
D. R.
,
Beaglehole
,
R.
,
Bernstein
,
A.
,
Borysiewicz
,
L. K.
,
Colagiuri
,
S.
,
Ganguly
,
N.
,
Glass
,
R. I.
,
Finegood
,
D. T.
,
Koplan
,
J.
,
Nabel
,
E. G.
,
Sarna
,
G.
,
Sarrafzadegan
,
N.
,
Smith
,
R.
,
Yach
,
D.
, and
Bell
,
J.
, 2007, “
Grand Challenges in Chronic Non-Communicable Diseases
,”
Nature (London)
0028-0836,
450
, pp.
494
496
.
5.
Wolf
,
M.
, and
Bailey
,
S.
, 2007, “
Improving Prescription Drug Labeling
,”
N. C Med. J.
0029-2559,
68
(
5
), pp.
340
342
.
6.
Bayser Consulting
, 2002, “
Compliance and Persistence
,” www.bayser.com/compliance.htmwww.bayser.com/compliance.htm
7.
Families USA Foundation
, 2000,
Cost Overdose: Growth in Drug Spending for the Elderly 1992–2010
,
Families USA
,
Washington, DC
.
8.
Jones
,
E. C.
, and
Chung
,
C. A.
, 2008,
RFID in Logistics: A Practical Introduction
,
CRC
,
Boca Raton, FL
.
9.
RFID security
, data protection and privacy, health and safety issues (2009). Retrieved Nov. 2009, from RFID Consultation Website of the European Commision: a service by CE RFID: http://www.rfidconsultation.eu/41/38/264.htmlhttp://www.rfidconsultation.eu/41/38/264.html
10.
Seevers
,
R. H.
, Report to FDA of PQRI RFID Working Group, December 1, 2005, www.pqri.org/pdfs/RFID Report to FDA 23Mar2006.pdfwww.pqri.org/pdfs/RFID Report to FDA 23Mar2006.pdf, p. 4/14.
12.
U.S. Department of Health and Human Services Food and Drug Administration
, 2008, “
Addendum to FDA’s Guidance for Industry: PDMA Pedigree Requirements—Questions and Answers Related to the Preliminary Injunction Ordered 12/5/06 in RXUSA Wholesalers, Inc. v. HHS
,” http://www.fda.gov/cder/regulatory/PDMA/PDMA_addendum.pdfhttp://www.fda.gov/cder/regulatory/PDMA/PDMA_addendum.pdf
13.
U.S. Department of Health and Human Services Food and Drug Administration
, 2008, “
Guidance for Industry: Prescription Drug Marketing Act (PDMA) Requirements—Questions and Answers
, http://www.fda.gov/OHRMS/DOCKETS/98fr/06d-0226-gdl0003.pdfhttp://www.fda.gov/OHRMS/DOCKETS/98fr/06d-0226-gdl0003.pdf
14.
Young
,
D.
, 2006, “
FDA: Regulations Will Clarify Pedigree Requirements: Loopholes Remain in PDMA Law
,”
Am. J. Health Syst. Pharm.
1079-2082,
63
, pp.
1306
1312
.
15.
Burt
,
J.
, 2005, “
RFID Project Safeguards Drug
,”
eWEEK
,
22
, p.
E1
.
16.
Thompson
,
C. A.
, 2004, “
Radio Frequency Tags for Identifying Legitimate Drug Products Discussed by Tech Industry
,”
Am. J. Health Syst. Pharm.
1079-2082,
61
, pp.
1430
1432
.
17.
Mun
,
I. K.
,
Kantrowitz
,
A. B.
,
Carmel
,
P. W.
,
Mason
,
K. P.
, and
Engels
,
D. W.
, 2007, “
Active RFID System Augmented With 2D Barcode for Asset Management in a Hospital Setting
,”
2007 IEEE International Conference on RFID
, Gaylord Texan Resort, Grapevine, TX, Mar. 26–28.
18.
Sangwan
,
R. S.
,
Qiu
,
R. G.
, and
Jessen
,
D.
, 2005, “
Using RFID Tags for Tracking Patients, Charts and Medical Equipment Within an Integrated Health Delivery Network
,”
2005 IEEE Networking, Sensing and Control
, Mar. 19–22, Paper No. ICNSC2005, p.
1070
.
20.
Rogers
,
A.
,
Jones
,
E.
, and
Oleynikov
,
D.
, 2007, “
Radio Frequency Identification (RFID) Applied to Surgical Sponges
,”
Surg. Endosc.
,
21
, pp.
1235
1237
.
21.
Li
,
C. J.
,
Liu
,
L.
,
Chen
,
S. Z.
,
Wu
,
C. C.
,
Huang
,
C. H.
, and
Chen
,
X. M.
, 2004, “
Mobile Healthcare Service System Using RFID
,”
Conference Proceedings of the 2004 IEEE International Conference on Networking, Sensing and Control
, Mar. 21–23, p.
1014
.
22.
Sandler
,
S. G.
,
Langeberg
,
A.
,
DeBandi
,
L.
,
Gibble
,
J.
,
Wilson
,
C.
, and
Feldman
,
C. L.
, 2007, “
Radiofrequency Identification Technology Can Standardize and Document Blood Collections and Transfusions
,”
Transfusion (Bethesda, Md.)
0041-1132,
47
, pp.
763
770
.
23.
Philipose
,
M.
, and
Smith
,
J. R.
, 2005, “
Battery-Free Wireless Identification and Sensing
,”
IEEE Pervasive Comput.
1536-1268,
4
, pp.
37
45
.
24.
Troyk
,
P. R.
, 1999, “
Injectable Electronic Identification, Monitoring, and Stimulation Systems
,”
Annu. Rev. Biomed. Eng.
1523-9829,
1
, pp.
177
209
.
25.
Ativanichayaphong
,
T.
,
Wang
,
J.
,
Huang
,
W. -D.
,
Rao
,
S.
,
Tibbals
,
H. F.
,
Tang
,
S. -J.
,
Spechler
,
S. J.
,
Stephanou
,
H.
, and
Chiao
,
J. -C.
, 2007, “
Development of an Implanted RFID Impedance Sensor for Detecting Gastroesophageal Reflux
,”
2007 IEEE International Conference on RFID
, Gaylord Texan Resort, Grapevine, TX, Mar. 26–28.
26.
Fontanazza
,
M.
, 2007, “
RFID Implant Tracks Reflux With Accuracy and Comfort
,”
Med. Device Diagn. Ind.
0194-844X,
August
, p.
38
.
27.
D.
Mishkin
,
R.
Chuttani
,
J.
Croffie
,
J.
DiSario
,
J.
Liu
,
R.
Shah
,
L.
Somogyi
,
W.
Tierney
,
L.
Wong Kee Song
, and
B.
Petersen
, 2006, “
ASGE Technology Status Evaluation Report: Wireless Capsule Endoscopy
,”
Gastrointest. Endosc.
0016-5107,
63
(
4
), pp.
539
545
.
28.
Carey
,
D.
, 2006, “
Camera in a Pill Surveys GI Tract
,” Retrieved on Feb. 4, 2008 from EE Times Europe: Global News for the Creators of Technology, http://eetimes.eu/environment/192200168http://eetimes.eu/environment/192200168
29.
Maqbool
,
S.
,
Parkman
,
H. P.
, and
Friedenberg
,
F. K.
, 2009, “
Wireless Capsule Motility: Comparison of the SmartPill® GI Monitoring System With Scintigraphy for Measuring Whole Gut Transit
,”
Dig. Dis. Sci.
0163-2116,
54
(
10
), pp.
2167
2174
.
30.
Guelfi
,
M.
,
Apollonio
,
F.
,
Grazioli
,
N.
,
Nocentini
,
S.
,
Marroco
,
G.
, and
Lovisolo
,
G. A.
, 1997, “
Dosimetric Procedures for Compliance Tests of Mobile Communication Devices
,”
Phys. Medica
1120-1797,
13
(
1
), pp.
11
16
.
31.
Lovisolo
,
G. A.
,
Pinto
,
R.
,
Ardoino
,
L.
, and
Manini
,
S.
, 2001, “
Dosimetric Techniques for the Evaluation of the E. M. Power Absorption Induced by Cellular Phones
,”
Radiat. Prot. Dosim.
0144-8420,
97
(
4
), pp.
369
374
.
32.
Marrocco
,
G.
, 2007, “
RFID Antennas for the UHF Remote Monitoring of Human Subjects
,”
IEEE Trans. Antennas Propag.
0018-926X,
55
, pp.
1862
1870
.
33.
Herrerias
,
J.
,
Leighton
,
J.
,
Costamagna
,
G.
,
Infantolino
,
A.
,
Eliakim
,
R.
,
Fischer
,
D.
,
Rubin
,
D.
,
Manten
,
H.
,
Scapa
,
E.
,
Morgan
,
D.
,
Bergwerk
,
A.
,
Koslowsky
,
B.
, and
Adler
,
S.
, 2008, “
Agile Patency System Eliminates Risk of Capsule Retention in Patients With Known Intestinal Strictures Who Undergo Capsule Endoscopy
,”
Gastrointest. Endosc.
0016-5107,
67
(
6
), pp.
902
909
.
34.
Marcus
,
M. B.
, 2008, “
Smart’ Pillbox Remembers So Patients Will Not Forget
,”
USA Today
0734-7456,
March
, p.
4D
.
You do not currently have access to this content.