Gravity balancing is often used in industrial machines to decrease the required actuator efforts during motion. In this paper, we present a new design for gravity balancing of the human leg using an external orthosis. This external orthosis is connected to the human leg on the shank and its other end is fixed to a walking frame. The major issues addressed in this paper are as follows: (i) design for gravity balancing of the human leg and the orthosis, (ii) kinematic compatibility of the human leg and the external orthosis during walking, and (iii) comparison of the joint torque trajectories of the human leg with and without external orthosis. We illustrate feasible 2D and 3D designs of the external orthosis through computer simulations. Our results show that the 3D design has smaller inertia with respect to 2D design, which can be more helpful for typical stroke patients to walk in a balanced position.
Skip Nav Destination
e-mail: fattah@cc.iut.ac.ir
e-mail: khatere.hajizade@gmail.com
e-mail: agrawal@udel.edu
Article navigation
March 2011
Research Papers
Gravity Balancing of a Human Leg Using an External Orthosis
Abbas Fattah,
Abbas Fattah
Department of Mechanical Engineering,
e-mail: fattah@cc.iut.ac.ir
Isfahan University of Technology
, Isfahan 841568111, Iran
Search for other works by this author on:
Khatereh Hajizadeh,
Khatereh Hajizadeh
Department of Mechanical Engineering,
e-mail: khatere.hajizade@gmail.com
Isfahan University of Technology
, Isfahan 841568111, Iran; Department of Mechanical Engineering, National University of Singapore
, Singapore, 117576
Search for other works by this author on:
Sunil K. Agrawal
Sunil K. Agrawal
Department of Mechanical Engineering,
e-mail: agrawal@udel.edu
University of Delaware
, Newark, DE 19716
Search for other works by this author on:
Abbas Fattah
Department of Mechanical Engineering,
Isfahan University of Technology
, Isfahan 841568111, Irane-mail: fattah@cc.iut.ac.ir
Khatereh Hajizadeh
Department of Mechanical Engineering,
Isfahan University of Technology
, Isfahan 841568111, Iran; Department of Mechanical Engineering, National University of Singapore
, Singapore, 117576e-mail: khatere.hajizade@gmail.com
Sunil K. Agrawal
Department of Mechanical Engineering,
University of Delaware
, Newark, DE 19716e-mail: agrawal@udel.edu
J. Med. Devices. Mar 2011, 5(1): 011002 (10 pages)
Published Online: February 3, 2011
Article history
Received:
August 28, 2009
Revised:
November 12, 2010
Online:
February 3, 2011
Published:
February 3, 2011
Citation
Fattah, A., Hajizadeh, K., and Agrawal, S. K. (February 3, 2011). "Gravity Balancing of a Human Leg Using an External Orthosis." ASME. J. Med. Devices. March 2011; 5(1): 011002. https://doi.org/10.1115/1.4003329
Download citation file:
Get Email Alerts
Cited By
Related Articles
On the Design of a Passive Orthosis to Gravity Balance Human Legs
J. Mech. Des (July,2005)
Design and Simulation of a Pneumatic, Stored-energy, Hybrid Orthosis
for Gait Restoration
J Biomech Eng (November,2005)
An Improved Smart Ankle Foot Othosis Design Using Dual Fluid Power Cylinders
J. Med. Devices (June,2010)
A Novel Device to Evaluate the Stiffness of Ankle-Foot Orthosis Devices
J Biomech Eng (December,2003)
Related Proceedings Papers
Related Chapters
Piping Design
Power Boilers: A Guide to the Section I of the ASME Boiler and Pressure Vessel Code, Second Edition
Application of and Optimum Design for Gravity Retaining Wall with Complex Algorithm Theory
Geological Engineering: Proceedings of the 1 st International Conference (ICGE 2007)
Supports
Process Piping: The Complete Guide to ASME B31.3, Third Edition