Fatal arrhythmias and ventricular fibrillation (VF) which lead to sudden cardiac death are believed to be preceded by alternans, observed as a beat-to-beat variation of the T-wave amplitude on the ECG [1,2]. Previous studies to predict the onset of alternans involved the restitution curve, the functional relationship between the action potential duration (APD) and preceding diastolic interval (DI). It was hypothesized that alternans appears when the magnitude of the slope of the restitution curve exceeds one [3]. However, this hypothesis failed in various experimental studies [4]. One of the main reasons for failure of the restitution hypothesis was the fact that it was derived under assumption of constant or periodic pacing, where there is an inherent dependence of the DI on the immediate preceding APD. During periodic pacing, small changes in DI are translated into subsequent changes in the APD and thus...
Skip Nav Destination
University of Minnesota,
Minneapolis, MN 55455
University of Minnesota,
Minneapolis, MN 55455
University of Minnesota,
Minneapolis, MN 55455
Article navigation
June 2014
Technical Briefs
Miniaturized Radio Frequency Telemetric Pacemaker With Anti-Arrhythmic Pacing Protocol1
Kanchan Kulkarni,
University of Minnesota,
Minneapolis, MN 55455
Kanchan Kulkarni
Department of Biomedical Engineering
,University of Minnesota,
312 Church St. S.E.
,Minneapolis, MN 55455
Search for other works by this author on:
Sze Yuen Tan,
University of Minnesota,
Minneapolis, MN 55455
Sze Yuen Tan
Department of Biomedical Engineering
,University of Minnesota,
312 Church St. S.E.
,Minneapolis, MN 55455
Search for other works by this author on:
Elena G. Tolkacheva
University of Minnesota,
Minneapolis, MN 55455
Elena G. Tolkacheva
Department of Biomedical Engineering
,University of Minnesota,
312 Church St. S.E.
,Minneapolis, MN 55455
Search for other works by this author on:
Kanchan Kulkarni
Department of Biomedical Engineering
,University of Minnesota,
312 Church St. S.E.
,Minneapolis, MN 55455
Sze Yuen Tan
Department of Biomedical Engineering
,University of Minnesota,
312 Church St. S.E.
,Minneapolis, MN 55455
Elena G. Tolkacheva
Department of Biomedical Engineering
,University of Minnesota,
312 Church St. S.E.
,Minneapolis, MN 55455
DOI: 10.1115/1.4027009
Manuscript received February 21, 2014; final manuscript received February 28, 2014; published online April 28, 2014. Editor: Arthur G. Erdman.
J. Med. Devices. Jun 2014, 8(2): 020909 (2 pages)
Published Online: April 28, 2014
Article history
Received:
February 21, 2014
Revision Received:
February 28, 2014
Citation
Kulkarni, K., Yuen Tan, S., and Tolkacheva, E. G. (April 28, 2014). "Miniaturized Radio Frequency Telemetric Pacemaker With Anti-Arrhythmic Pacing Protocol." ASME. J. Med. Devices. June 2014; 8(2): 020909. https://doi.org/10.1115/1.4027009
Download citation file:
Get Email Alerts
Cited By
Related Articles
A Novel Ex Vivo Heart Model for the Assessment of Cardiac Pacing Systems
J Biomech Eng (November,2005)
Design of an Experimental Test System to Investigate Parameters Affecting Distal Tip Loads of Pacemaker and Defibrillator Leads
J. Med. Devices (March,2015)
Impacts of Wireless Power on Medical Device Design Safety
J. Med. Devices (June,2009)
Simulation of LV Pacemaker Lead in Marginal Vein: Potential Risk Factors for Acute Dislodgement
J Biomech Eng (March,2011)
Related Proceedings Papers
Related Chapters
Formal Development and Automatic Code Generation: Cardiac Pacemaker
International Conference on Electronics, Information and Communication Engineering (EICE 2012)
Why Do We Avoid Conflict?
Conflict Resolution: Concepts and Practice (The Technical Manager's Survival Guides)
Introduction
Thermal Management of Telecommunication Equipment, Second Edition