Over 58,000 patients suffer from renal cell carcinoma annually in the United States. Treatment for this cancer often requires surgical removal of the cancerous tissue in a partial nephrectomy procedure. In open renal surgery, the kidney is placed on ice to increase allowable ischemia time; however, there is no widely accepted method for reducing kidney temperature during minimally invasive surgery. A novel device has been designed, prototyped, and evaluated to perform effective renal cooling during minimally invasive kidney surgery to reduce damage due to extended ischemia. The device is a fluid-containing bag with foldable cooling surfaces that wrap around the organ like a taco shell. It is deployed through a 12 mm trocar, wrapped around the kidney and secured using bulldog clamps. The device then fills with an ice slurry and remains on the kidney for up to 20 min. The ice slurry is then removed from the device and the device is retracted from the body. Tests of the prototype show that the device successfully cools porcine kidneys from to in 5 minutes.
Skip Nav Destination
Article navigation
Design Of Medical Devices Conference Abstracts
Innovative Renal Cooling Device for Use in Minimally Invasive Surgery
Ed Summers,
Ed Summers
Massachusetts Institute of Technology
Search for other works by this author on:
Thomas Cervantes,
Thomas Cervantes
Massachusetts Institute of Technology
Search for other works by this author on:
Rachel Batzer,
Rachel Batzer
Massachusetts Institute of Technology
Search for other works by this author on:
Julia Stark,
Julia Stark
Massachusetts Institute of Technology
Search for other works by this author on:
Raymond Lewis
Raymond Lewis
Massachusetts Institute of Technology
Search for other works by this author on:
Ed Summers
Massachusetts Institute of Technology
Thomas Cervantes
Massachusetts Institute of Technology
Rachel Batzer
Massachusetts Institute of Technology
Julia Stark
Massachusetts Institute of Technology
Raymond Lewis
Massachusetts Institute of Technology
J. Med. Devices. Jun 2011, 5(2): 027536 (1 pages)
Published Online: June 15, 2011
Article history
Online:
June 15, 2011
Published:
June 15, 2011
Citation
Summers, E., Cervantes, T., Batzer, R., Stark, J., and Lewis, R. (June 15, 2011). "Innovative Renal Cooling Device for Use in Minimally Invasive Surgery." ASME. J. Med. Devices. June 2011; 5(2): 027536. https://doi.org/10.1115/1.3591386
Download citation file:
Get Email Alerts
Cited By
Related Articles
Evaluation of a Novel Method of Shunting for Patients With Normal Pressure Hydrocephalus
J. Med. Devices (June,2011)
An Advanced Patient Lift and Transfer Device for the Home
J. Med. Devices (March,2010)
A Hydraulically Controlled Nonoperative Magnetic Treatment for Long Gap Esophageal Atresia
J. Med. Devices (June,2011)
Proposed Protocol for Objective Morcellator Analysis
J. Med. Devices (June,2011)
Related Proceedings Papers
Related Chapters
Investigation of the Energy Shielding of Kidney Stones by Cavitation Bubble Clouds during Burst Wave Lithotripsy
Proceedings of the 10th International Symposium on Cavitation (CAV2018)
Modeling, Simulating, and Synthesizing of Simplified Renal Mechanism
Intelligent Engineering Systems Through Artificial Neural Networks, Volume 17
Modeling, Simulating, and Synthesizing of Simplified Kidney Function
Intelligent Engineering Systems through Artificial Neural Networks Volume 18