Skip Nav Destination
Issues
September 2011
ISSN 1932-6181
EISSN 1932-619X
In this Issue
Research Papers
Design and Evaluation of a Computer-Controlled Pressure Algometer
J. Med. Devices. September 2011, 5(3): 031002.
doi: https://doi.org/10.1115/1.4004416
Design and Control of a Pneumatic Artificial Muscle Actuated Above-Knee Prosthesis
J. Med. Devices. September 2011, 5(3): 031003.
doi: https://doi.org/10.1115/1.4004417
Topics:
Design
,
Knee
,
Muscle
,
Prostheses
,
Locomotives
,
Torque
Development of a New Method for Pulse Push/Pull Hemodialysis
J. Med. Devices. September 2011, 5(3): 031004.
doi: https://doi.org/10.1115/1.4004316
Topics:
Blood
,
Filtration
,
Flow (Dynamics)
,
Fluids
,
Hemodialysis
,
Kidney
,
Pumps
,
Patient treatment
,
Convection
,
Tubing
Development of a Colonoscope Sheath Device for Colonoscopy
J. Med. Devices. September 2011, 5(3): 031005.
doi: https://doi.org/10.1115/1.4004418
Topics:
Endoscopes
,
Stiffness
,
Stability
A Cyclic Robot for Lower Limb Exercise
J. Med. Devices. September 2011, 5(3): 031006.
doi: https://doi.org/10.1115/1.4004648
Topics:
Design
,
Inertia (Mechanics)
,
Robots
,
Actuators
,
Damping
,
Machinery
,
Haptics
,
Simulation
On Modeling Assumptions in Finite Element Analysis of Stents
J. Med. Devices. September 2011, 5(3): 031007.
doi: https://doi.org/10.1115/1.4004654
Topics:
Diamonds
,
Finite element analysis
,
Modeling
,
Stents
,
Manufacturing
,
Fatigue
,
Shapes
,
Nickel titanium alloys
,
Simulation
,
Dimensions
Pump Design for a Portable Renal Replacement System
J. Med. Devices. September 2011, 5(3): 031008.
doi: https://doi.org/10.1115/1.4004650
Topics:
Design
,
Flow (Dynamics)
,
Pumps
,
Kidney
Design of a Multigrasp Transradial Prosthesis
J. Med. Devices. September 2011, 5(3): 031009.
doi: https://doi.org/10.1115/1.4004653
Topics:
Design
,
Motors
,
Prostheses
,
Tendons
,
Artificial limbs
,
Pulleys
Gait Phase-Based Control for a Rotary Series Elastic Actuator Assisting the Knee Joint
J. Med. Devices. September 2011, 5(3): 031010.
doi: https://doi.org/10.1115/1.4004793
Topics:
Actuators
,
Control equipment
,
Knee
,
Modeling
,
Motors
,
Sliding mode control
,
Torque
,
Errors
,
Boundary layers
,
Design
Gamma Irradiation Studies I. Dental Grafts
Selcan Türker, A. Yekta Özer, Burak Kutlu, Rahime Nohutcu, Hasan Bilgili, Didem Öztürk, Meral Özalp, Arzu Sungur
J. Med. Devices. September 2011, 5(3): 031011.
doi: https://doi.org/10.1115/1.4004647
Effects of Microneedle Design Parameters on Hydraulic Resistance
J. Med. Devices. September 2011, 5(3): 031012.
doi: https://doi.org/10.1115/1.4004833
Topics:
Microneedles
,
Needles
,
Tubing
,
Flow (Dynamics)
,
Design
,
Poiseuille flow
,
Fluids
Technical Briefs
Method to Achieve High Frame Rates in a Scanning Fiber Endoscope
J. Med. Devices. September 2011, 5(3): 034501.
doi: https://doi.org/10.1115/1.4004646
Topics:
Braking
,
Endoscopes
,
Fibers
,
Imaging
,
Displacement
,
Cycles
Biomechanical Property of a Natural Microneedle: The Caterpillar Spine
J. Med. Devices. September 2011, 5(3): 034502.
doi: https://doi.org/10.1115/1.4004651
Topics:
Biomechanics
,
Drug delivery systems
,
Elastic moduli
,
Fracture (Materials)
,
Fracture (Process)
,
Microneedles
,
Skin
,
Failure
,
Design
,
Buckling
Steerable Mechanical Joint for High Load Transmission in Minimally Invasive Instruments
J. Med. Devices. September 2011, 5(3): 034503.
doi: https://doi.org/10.1115/1.4004649
Topics:
Cutting
,
Deflection
,
Design
,
Engineering prototypes
,
Instrumentation
,
Rolling contact
,
Stiffness
,
Stress
,
Wire
,
Steel
Design Innovation
Evolution of a Novel Intraductal Patent Ductus Arteriosus Occlusion Device
Megha Agrawal, Vaibhavi A. Sonetha, Smriti Sharma, Satyajeet Parakh, Bharat Dalvi, Jayesh R. Bellare
J. Med. Devices. September 2011, 5(3): 035001.
doi: https://doi.org/10.1115/1.4003674
Topics:
Adhesion
,
Biomedicine
,
Blood
,
Design
,
Ducts
,
Fibers
,
Flow (Dynamics)
,
Manufacturing
,
Nickel titanium alloys
,
Patents
Errata
Erratum: “Design and Preliminary Testing of a Novel Dual-Chambered Syringe” [Journal of Medical Devices, 2011, 5(2), 021003]
J. Med. Devices. September 2011, 5(3): 037001.
doi: https://doi.org/10.1115/1.4004929
Topics:
Biomedical equipment
,
Design
,
Medical devices
,
Surface tension
,
Testing
Email alerts
RSS Feeds
Context-Driven Design of a Laparoscopic Instrument Cleaner for Use in Rural Low-Resource Hospitals
J. Med. Devices (March 2025)
Controlled Ice Nucleation With a Sand-PDMS Film Device Enhances Cryopreservation of Mouse Preantral Ovarian Follicles
J. Med. Devices (December 2024)
Review of Blood and Fluid Warming Methods
J. Med. Devices (December 2024)