The thickness at which the calandria vault floor in a generic CANDU 6 nuclear reactor may collapse while undergoing molten core–concrete interaction (MCCI) was studied using an approximate analytical model and a finite-element model. It was confirmed that the collapse criterion of 0.45 m floor thickness that is currently used in severe accident analyses is adequate. The estimated timing of collapse is subject to uncertainty of several hours.
Issue Section:
Special Section Papers
Topics:
Accidents,
Collapse,
Concretes,
Finite element model,
Stress,
Temperature,
Thermal expansion,
Failure
References
1.
Nitheanandan
, T.
, and Brown
, M. J.
, 2013
, “Backup and Ultimate Heat Sinks in CANDU Reactors for Prolonged SBO Accidents
,” Nucl. Eng. Technol.
, 45
(5
), pp. 589
–596
.2.
Roark
, R. J.
, Young
, W. C.
, and Budynas
, R. G.
, 2002
, Roark's Formulas for Stress and Strain
, McGraw-Hill
, New York.3.
Mills
, A. F.
, 1999
, Heat Transfer
, 2nd ed., Prentice Hall
, Upper Saddle River, NJ.4.
Naus
, D. J.
, 2010
, “A Compilation of Elevated Temperature Concrete Material Property Data and Information for Use in Assessments of Nuclear Power Plant Reinforced Concrete Structures
,” U.S. NRC, Washington, DC, Technical Report No. NUREG/CR-7031.5.
ANSYS
, 2015
, “ANSYS Mechanical User's Guide
,” ANSYS, Inc., Canonsburg, PA.6.
Dinh
, T. N.
, and Petukhov
, S. M.
, 1993
, “Development of the Inverse Heat Conduction Method and Its Application to the Study of the Molten Core-Concrete Interaction Problem
,” NURETH-6 Topical Meeting Proceedings
, Grenoble, France, pp. 755–761.Copyright © 2017 by ASME