The thickness at which the calandria vault floor in a generic CANDU 6 nuclear reactor may collapse while undergoing molten core–concrete interaction (MCCI) was studied using an approximate analytical model and a finite-element model. It was confirmed that the collapse criterion of 0.45 m floor thickness that is currently used in severe accident analyses is adequate. The estimated timing of collapse is subject to uncertainty of several hours.

References

1.
Nitheanandan
,
T.
, and
Brown
,
M. J.
,
2013
, “
Backup and Ultimate Heat Sinks in CANDU Reactors for Prolonged SBO Accidents
,”
Nucl. Eng. Technol.
,
45
(
5
), pp.
589
596
.
2.
Roark
,
R. J.
,
Young
,
W. C.
, and
Budynas
,
R. G.
,
2002
,
Roark's Formulas for Stress and Strain
,
McGraw-Hill
, New York.
3.
Mills
,
A. F.
,
1999
,
Heat Transfer
, 2nd ed.,
Prentice Hall
, Upper Saddle River, NJ.
4.
Naus
,
D. J.
,
2010
, “
A Compilation of Elevated Temperature Concrete Material Property Data and Information for Use in Assessments of Nuclear Power Plant Reinforced Concrete Structures
,” U.S. NRC, Washington, DC, Technical Report No. NUREG/CR-7031.
5.
ANSYS
,
2015
, “
ANSYS Mechanical User's Guide
,” ANSYS, Inc., Canonsburg, PA.
6.
Dinh
,
T. N.
, and
Petukhov
,
S. M.
,
1993
, “
Development of the Inverse Heat Conduction Method and Its Application to the Study of the Molten Core-Concrete Interaction Problem
,”
NURETH-6 Topical Meeting Proceedings
, Grenoble, France, pp. 755–761.
You do not currently have access to this content.