Abstract

A fast breeder reactor (FBR) is considered as the promising technology in terms of load reduction on the environment, because the FBR has capability to improve usage efficiency of uranium resources and can reduce high-level radioactive waste which needs to be managed for millions of years. A cold trap is one of the important components in the FBR to control the impurity concentration of the liquid sodium. For accurate evaluation of the cold trap performance, we have been proposing the three-dimensional (3D) numerical analysis method of the cold trap. In this method, the evaluation of the impurity precipitation phenomena on the surface of the mesh wire of the cold trap is the key. For this, the numerical analysis method which is based on the lattice kinetic scheme (LKS) has been proposed. In order to apply the LKS to the impurity precipitation simulation of the cold trap, two models (the low Reynolds number model and the impurity precipitation model) have been developed. In this paper, we focused on the validation of these models. To confirm the validity of the low Reynolds number model, the Chapman–Enskog analysis was applied to the low Reynolds number model. As a result, it has been theoretically confirmed that the low Reynolds number model can recover the correct macroscopic equations (incompressible Navier–Stokes equations) with small error. The low Reynolds number model was also validated by the numerical simulation of two-dimensional (2D) channel flow problem with the low Reynolds number conditions which correspond to the actual cold trap conditions. These results have confirmed that the error of the low Reynolds number model is ten times smaller than that of the original LKS. The validity of the impurity precipitation model was investigated by the comparison to the precipitation experiments. In this comparison, the mesh convergence study was also conducted. These results have confirmed that the proposed impurity precipitation model can simulate the impurity precipitation phenomena on the surface of the mesh wire. It has been also confirmed that the proposed impurity precipitation model can simulate the impurity precipitation phenomenon regardless of the cell size which were tested in this investigation.

References

1.
Goplen
,
B. C.
,
Biery
,
J. C.
, and
McPheeters
,
C. C.
,
1970
, “Numerical Simulation of a Cold Trap for Sodium Purification,” UC-80, Reactor Technology, TID-4500, Los Alamos Scientific Laboratory, Los Alamos, NM, Report No.
LA-4435
.https://digital.library.unt.edu/ark:/67531/metadc870277/
2.
McPheeters
,
C. C.
, and
Raue
,
D. J.
,
1974
, “Sodium Hydride Precipitation in Sodium Cold Traps,” Argonne National Laboratory, DuPage County, IL, Report No.
ANL-79-101
.https://inis.iaea.org/search/search.aspx?orig_q=RN:11532091
3.
Murase
,
M.
,
Sumida
,
I.
,
Kotani
,
K.
, and
Yamamoto
,
H.
,
1978
, “
Impurity Interaction Analysis in Mesh-Packed Cold Traps
,”
Nucl. Technol.
,
37
(2), pp.
138
147
.
4.
Murase
,
M.
,
Sumida
,
I.
,
Nagase
,
N.
,
Mukai
,
K.
, and
Onuki
,
O.
,
1980
, “
Impurity Deposition in a Mesh-Packed Cold Trap
,”
Nucl. Technol.
,
48
(3), pp.
196
203
.
5.
Murase
,
M.
,
Sumida
,
I.
,
Kotani
,
K.
, and
Yamamoto
,
H.
,
1978
, “
Performance Analysis of Mesh-Packed Cold Traps
,”
J. Nucl. Sci. Technol.
,
15
(
9
), pp.
711
713
.
6.
Hemanath
,
M. G.
,
Meikandamurthy
,
C.
,
Ashok kumar
,
A.
,
Chandramouli
,
S.
,
Rajan
,
K. K.
,
Rajan
,
M.
,
Vaidyanathan
,
G.
,
Padmakumar
,
G.
, and
Raj
,
B.
,
2010
, “
Theoretical and Experimental Performance Analysis for Cold Trap Design
,”
Nucl. Eng. Des.
,
240
(
10
), pp.
2737
2744
.
7.
Kwang
,
R. K.
,
Ji
,
Y. J.
,
Kyung
,
C. J.
,
Sang
,
W. K.
, and
Sung
,
T. H.
,
1998
, “
Theoretical Analysis on the Sodium Purification for Cold Trap Design and Performance Measurement
,”
J. Ind. Eng. Chem.
,
4
(
2
), pp.
113
121
.https://www.cheric.org/PDF/JIEC/IE04/IE04-2-0113.pdf
8.
Kumaev
,
V. Y.
,
Alexeev
,
V. V.
,
Kozlov
,
F. A.
, and
Piroogov
,
E. P.
,
2012
, “
Numerical Simulation of Impurity Mass Transfer in the Cold Traps in Fast Reactors
,”
At. Energy
,
112
(
3
), pp.
214
217
.
9.
Khatcheressian
,
N.
,
Latge
,
C.
,
Joulia
,
X.
,
Gilardi
,
T.
, and
Meyer
,
X.
,
2012
, “
Modelling of Cold Traps for Sodium Purification in Fast Reactor
,”
22nd European Symposium on Computer Aided Process Engineering
, London, June 17–20, pp.
1033
1037
.https://inis.iaea.org/search/search.aspx?orig_q=RN:45095883
10.
Tamura
,
A.
,
Takahashi
,
S.
,
Nakata
,
H.
, and
Takota
,
A.
,
2017
, “
Development of Evaluation Method for Cold Trap in Fast Breeder Reactor: Part 1—Numerical Analysis of Impurity Precipitation on Mesh Wire
,”
ASME
Paper No. ICONE25-67702.
11.
Takahashi
,
S.
,
Tamura
,
A.
,
Nakata
,
H.
, and
Takota
,
A.
,
2017
, “
Development of Evaluation Method for Cold Trap in Fast Breeder Reactor: Part 2—Analytical Evaluation of Impurity Capturing Capacity in Cold Trap
,”
ASME
Paper No. ICONE25-67699.
12.
Chen
,
H.
,
Chen
,
S.
, and
Matthaeus
,
W. H.
,
1992
, “
Recovery of the Navier–Stokes Equations Using a Lattice-Gas Boltzmann Method
,”
Phys. Rev. A
,
45
(
8
), pp.
5339
5342
.
13.
Qian
,
Y. H.
,
d'Humieres
,
D.
, and
Lallemand
,
P.
,
1992
, “
Lattice BGK Models for Navier–Stokes Equation
,”
Europhys. Lett.
,
17
(
6
), pp.
479
484
.
14.
He
,
X.
, and
Luo
,
L. S.
,
1997
, “
Theory of the Lattice Boltzmann Method: From the Boltzmann Equation to the Lattice Boltzmann Equation
,”
Phys. Rev. E
,
56
(
6
), pp.
6811
6817
.
15.
Chen
,
S.
, and
Doolen
,
D.
,
1998
, “
Lattice Boltzmann Method for Fluid Flows
,”
Annu. Rev. Fluid Mech.
,
30
(
1
), pp.
329
364
.
16.
Inamuro
,
T.
,
Yoshino
,
M.
, and
Ogino
,
F.
,
1999
, “
Lattice Boltzmann Simulation of Flows in a Three-Dimensional Porous Structure
,”
Int. J. Numer. Method Fluids
,
29
(
7
), pp.
737
748
.
17.
Inamuro
,
T.
,
2002
, “
A Lattice Kinetic Scheme for Incompressible Viscous Flows With Heat Transfer
,”
Philos. Trans. R. Soc. A
,
360
(
1792
), pp.
477
484
.
18.
Howe
,
M. S.
,
2003
,
Theory of Vortex Sound
,
Cambridge University Press
,
Cambridge, UK
.
You do not currently have access to this content.