Several types of radioactive gases are released from the nuclear reactor. In order to measure the activity of such gases, it is necessary to calculate the accurate efficiency. Practically, efficiency calibration with gaseous sources is not very easy because of the low half-lives of the noble gases. For this purpose, Monte Carlo (MC) simulation was performed to study the full energy peak efficiency of two n-type high-purity Germanium (HPGe) detectors. Two spheres of xenon and krypton composition sources with two nuclides (Xe133andKr85) and two-point sources were simulated, covering the energy range from 81 keV to 604 keV. Self-absorption correction factors were calculated with GEANT4 for two gas sphere samples and obtained good efficiency agreement with the experimental results. The simulation was performed for various gas samples with different densities and observed their effects on the full energy peak efficiency value of two detectors. The corresponding self-absorption correction factors were calculated for each gaseous sample and investigated that the self-absorption correction factors not only depend on the sample characteristics but also on the detector geometry and source to detector distance. The dependence of the full energy peak efficiency on the side cap wall material and their thicknesses were also carried out for some particular photon energies.

References

1.
Oishi
,
T.
,
Yoshida
,
M.
,
Saegusa
,
J.
,
Honda
,
T.
,
Takahashi
,
K.
, and
Kuwabara
,
H.
,
2001
, “
Determination of Detection Efficiency Curve for a Gas Monitor With a Built-in Germanium Detector
,”
J. Nucl. Sci. Technol.
,
38
(
3
), pp.
203
208
.
2.
Yoshida
,
M.
,
Oishi
,
T.
,
Saegusa
,
J.
,
Honda
,
T.
,
Takahashi
,
K.
, and
Kuwabara
,
H.
,
1999
, “
A Calibration Technique for Radioactive Gas Monitor With a Built-in Germanium Detector
,”
JAERI J.
,
10
, pp.
3a
151
.
3.
Kovar
,
P.
, and
Dryak
,
P.
,
2008
, “
Gaseous Standards Preparation With the Radionuclide Ar-41 for Stack Monitors Calibration and Verification in Nuclear Facilities
,”
Appl. Radiat. Isot.
,
66
(
6–7
), pp.
796
798
.
4.
Le Petit
,
G.
,
Jutier
,
C.
,
Gross
,
P.
, and
Greiner
,
V.
,
2006
, “
Low-Level Activity Measurement of 131Xem, 133Xem, 135Xe and 133Xe in Atmospheric Air Samples Using High-Resolution Dual X–γ Spectrometry
,”
Appl. Radiat. Isot.
,
64
(
10–11
), pp.
1307
1312
.
5.
Mostajaboddavati
,
M.
,
Hassanzadeh
,
S.
, and
Faghihian
,
H.
,
2006
, “
Efficiency Calibration and Measurement of Self-Absorption Correction for Environmental Gamma-Spectroscopy of Soil Samples Using Marinelli Beaker
,”
J. Radioanal. Nucl. Chem.
,
268
(
3
), pp.
539
544
.
6.
Khater
,
A.
, and
Ebaid
,
Y.
,
2008
, “
A Simplified Gamma-Ray Self-Attenuation Correction in Bulk Samples
,”
Appl. Radiat. Isot.
,
66
(
3
), pp.
407
413
.
7.
Robu
,
E.
, and
Giovani
,
C.
,
2009
, “
Gamma-Ray Self-Attenuation Corrections in Environmental Samples
,”
Rom. Rep. Phys.
,
61
(
2
), pp.
295
300
.
8.
Misiak
,
R.
,
Hajduk
,
R.
,
Stobiński
,
M.
,
Bartyzel
,
M.
,
Szarłowicz
,
K.
, and
Kubica
,
B.
,
2011
, “
Self-Absorption Correction and Efficiency Calibration for Radioactivity Measurement of Environmental Samples by Gamma-Ray Spectrometry
,”
Nukleonika
,
56
(
1
), pp.
23
28
.http://www.nukleonika.pl/www/back/full/vol56_2011/v56n1p023f.pdf
9.
Quindós
,
L.
,
Sainz
,
C.
,
Fuente
,
I.
,
Nicolás
,
J.
,
Quindós
,
L.
, and
Arteche
,
J.
,
2006
, “
Correction by Self-Attenuation in Gamma-Ray Spectrometry for Environmental Samples
,”
J. Radioanal. Nucl. Chem.
,
270
(
2
), pp.
339
343
.
10.
El-Khatib
,
A. M.
,
Thabet
,
A. A.
,
Elzaher
,
M. A.
,
Badawi
,
M. S.
, and
Salem
,
B. A.
,
2014
, “
Study on the Effect of the Self-Attenuation Coefficient on γ-Ray Detector Efficiency Calculated at Low and High Energy Regions
,”
Nucl. Eng. Technol.
,
46
(
2
), pp.
217
224
.
11.
Pibida
,
L.
,
Nafee
,
S.
,
Unterweger
,
M.
,
Hammond
,
M. M.
,
Karam
,
L.
, and
Abbas
,
M.
,
2007
, “
Calibration of HPGe Gamma-Ray Detectors for Measurement of Radioactive Noble Gas Sources
,”
Appl. Radiat. Isot.
,
65
(
2
), pp.
225
233
.
12.
Jose
,
M.
,
Baskar
,
S.
, and
Meenakshisundaram
,
V.
,
2010
, “
Estimation of Radioactive Noble Gas Activity in FBTR–a Simple Method of Calibration of HPGe Detector
,”
IRPA12: 12. Congress of the International Radiation Protection Association: Strengthening Radiation Protection Worldwide-Highlights, Global Perspective and Future Trends
, 1.
13.
Pilleyre
,
T.
,
Sanzelle
,
S.
,
Miallier
,
D.
,
Fain
,
J.
, and
Courtine
,
F.
,
2006
, “
Theoretical and Experimental Estimation of Self-Attenuation Corrections in Determination of 210Pb by γ-Spectrometry With Well Ge Detector
,”
Radiat. Meas.
,
41
(
3
), pp.
323
329
.
14.
Sarangapani
,
R.
,
Jose
,
M.
,
Srinivasan
,
T.
, and
Venkatraman
,
B.
,
2017
, “
Determination of Efficiency of an Aged HPGe Detector for Gaseous Sources by Self Absorption Correction and Point Source Methods
,”
J. Instrum.
,
12
(
7
), p.
T07006
.
15.
Saat
,
A.
,
Appleby
,
P.
, and
Nolan
,
1997
, “
Self-Absorption Corrections of Various Sample-Detector Geometries in Gamma-Ray Spectrometry Using Sample Monte Carlo Simulations
,” International Nuclear Conference: a new era in Nuclear Science and Technology, Oct. 27–28, Kuala Lumpur, Malaysia.
16.
Hardy
,
J.
,
Iacob
,
V.
,
Sanchez-Vega
,
M.
,
Effinger
,
R.
, and
Lipnik
,
P.
,
2002
, “
Precise Efficiency Calibration of an HPGe Detector: Source Measurements and Monte Carlo Calculations With Sub-Percent Precision
,”
Appl. Radiat. Isot.
,
56
(
1–2
), pp.
65
69
.
17.
Vargas
,
M. J.
,
Timón
,
A. F.
,
Dı́az
,
N. C.
, and
Sánchez
,
D. P.
,
2002
, “
Monte Carlo Simulation of the Self-Absorption Corrections for Natural Samples in Gamma-Ray Spectrometry
,”
Appl. Radiat. Isot.
,
57
(
6
), pp.
893
898
.
18.
Garcı́a-Talavera
,
M.
,
Neder
,
H.
,
Daza
,
M.
, and
Quintana
,
B.
,
2000
, “
Towards a Proper Modeling of Detector and Source Characteristics in Monte Carlo Simulations
,”
Appl. Radiat. Isot.
,
52
(
3
), pp.
777
783
.
19.
Hernández Suárez
,
F. J.
,
2002
, “
Optimisation of Environmental Gamma Spectrometry Using Monte Carlo Methods
,”
Acta Univ. Ups.
,
751
, p.
64
20.
Khan
,
W.
,
Zhang
,
Q.
,
He
,
C.
, and
Saleh
,
M.
,
2018
, “
Monte Carlo Simulation of the Full Energy Peak Efficiency of an HPGe Detector
,”
Appl. Radiat. Isot.
,
131
, pp.
67
70
.
You do not currently have access to this content.