This paper describes a method of improving the cooling of the hub region of high-pressure turbine (HPT) rotor by making better use of the unsteady coolant flows originating from the upstream vane. The study was performed computationally on an engine HPT stage with representative inlet hot streak and vane coolant conditions. An experimental validation study of hot streak migration was undertaken on two low-speed test facilities. The unsteady mechanisms that transport hot and cold fluid within the rotor hub region are first examined. It was found that vortex-blade interaction dominated the unsteady transport of hot and cold fluid in the rotor hub region. This resulted in the transport of hot fluid onto the rotor hub and pressure surface, causing a peak in the surface gas temperatures. The vane film coolant was found to have only a limited effect in cooling this region. A new cooling configuration was thus examined which exploits the unsteadiness in rotor hub to aid transport of coolant towards regions of high rotor surface temperatures. The new coolant was introduced from a slot upstream of the vane. This resulted in the feed of slot coolant at a different phase and location relative to the vane film coolant within the rotor. The slot coolant was entrained into the unsteady rotor secondary flows and transported towards the rotor hub-pressure surface region. The slot coolant reduced the peak time-averaged rotor temperatures by a similar amount as the vane film coolant despite having only a sixth of the coolant mass flow.
Skip Nav Destination
Article navigation
September 2012
Research Papers
Hot Streak and Vane Coolant Migration in a Downstream Rotor
Robert J. Miller
Robert J. Miller
Whittle Laboratory
, University of Cambridge
, 1 JJ Thomson Avenue, Cambridge, CB3 0DY, England
Search for other works by this author on:
Robert J. Miller
Whittle Laboratory
, University of Cambridge
, 1 JJ Thomson Avenue, Cambridge, CB3 0DY, England
J. Turbomach. Sep 2012, 134(5): 051002 (10 pages)
Published Online: May 7, 2012
Article history
Received:
January 7, 2011
Revised:
January 8, 2011
Online:
May 7, 2012
Published:
May 7, 2012
Citation
Ong, J., and Miller, R. J. (May 7, 2012). "Hot Streak and Vane Coolant Migration in a Downstream Rotor." ASME. J. Turbomach. September 2012; 134(5): 051002. https://doi.org/10.1115/1.4003832
Download citation file:
Get Email Alerts
Related Articles
Effect of Film Cooling on Turbine Capacity
J. Eng. Gas Turbines Power (January,2010)
Film-Cooling Effectiveness on a Rotating Turbine Platform Using Pressure Sensitive Paint Technique
J. Turbomach (October,2010)
Computational Study of a Midpassage Gap and Upstream Slot on Vane Endwall Film-Cooling
J. Turbomach (January,2011)
Estimating the Loss Associated With Film Cooling for a Turbine Stage
J. Turbomach (March,2012)
Related Proceedings Papers
Related Chapters
Outlook
Closed-Cycle Gas Turbines: Operating Experience and Future Potential
Control and Operational Performance
Closed-Cycle Gas Turbines: Operating Experience and Future Potential
Thermodynamic Performance
Closed-Cycle Gas Turbines: Operating Experience and Future Potential