This paper considers a technique for fault detection and localization based on time-domain transmissibility identification. This technique takes the advantage of unknown external (ambient) excitation to identify a sensor-to-sensor model, which is independent of the excitation signal and the initial conditions of the underlying system. In the presence of unknown external excitation, the identified transmissibility operator is used to compute the sensor-to-sensor residual, which is the discrepancy between the predicted sensor output (based on the transmissibility operator) and the actual measurements. The sensor-to-sensor residuals are used to detect, diagnose, and localize faults in sensors and system dynamics. We consider an experimental setup consisting of an acoustic system with three speakers and six microphones. Each speaker is an actuator, and each microphone is a sensor that measures the acoustic response at its location. Measurements from the six microphones are used to construct transmissibility operators, which in turn are used to detect and localize changes in the dynamics of the acoustic system or the microphones by computing the resulting one-step residuals.

Introduction

The study of structural vibration focuses on the displacement, velocity, and acceleration response of a structure to force and torque inputs. This response can be studied in terms of either transfer functions or differential equation models. In the former case, the frequency response of the structure can be estimated by computing the ratio of the transforms of the forcing and response signals. These procedures are based on the assumption that the input and output signals are stationary, and thus, initial conditions and transient effects are either assumed to be absent or are ignored. In the case of differential equation models, time-domain methods can be used to estimate the model parameters assuming that the input is sufficiently persistent. In this case, initial conditions and transient effects can enhance rather than degrade the accuracy of the estimated model. The effect of nonzero initial conditions on time-domain and frequency-domain identification is shown in Ref. [1].

An alternative approach to force-to-motion models is the class of models known as transmissibilities. A transmissibility is a relationship between identical variables, such as force-to-force, position-to-position, velocity-to-velocity, and acceleration-to-acceleration [2,3]. The input and output of a transmissibility, referred to as the pseudo input and pseudo output, respectively, are thus outputs of the underlying system. Although force-to-motion transfer functions can be identified using either time-domain or frequency-domain methods, transmissibility estimates are traditionally obtained using only frequency-domain methods, and this remains an active area of research [49].

Interestingly, time-domain methods have not been traditionally used to identify transmissibilities. The reason for this is partly due to the fact that the meaning of a transmissibility in the time domain is suspect. In particular, the input (forcing) to the underlying system plays no visible role in the transmissibility, and the states of the transmissibility have no physical interpretation. Nevertheless, for applications in which response data have a significant nonstationary component, it is advantageous to use time-domain methods to estimate transmissibility functions. A step in this direction was taken in Refs. [1,1013], where time-domain transmissibility models were obtained. These models, called pseudo transfer functions, are formulated in terms of the differential operator p=d/dt rather than the Laplace s. This framework requires some care due to the fact that p is not a complex number. In addition, unlike input–output transfer functions in the Laplace domain, the differentiation operator accounts for the free response in the time domain [12], but requires special attention due to issues of causality, stability, and order. In particular, a time-domain transmissibility model may be noncausal (in either continuous time or discrete time), where its numerator and denominator dynamics are the zero dynamics of the underlying transfer functions from the forcing to the respective motion sensors.

Various fault-detection techniques have been introduced in the literature [1417]. In some cases, health monitoring can be performed by exciting the system in a controlled manner, using a plant model and observer to predict the response, and comparing the measured response to the prediction [1820]. This approach, known as active fault detection, is based on residual generation. In contrast, passive fault detection detects faults by analyzing the sensor signals alone and searching for anomalies [2123].

In the present paper, we focus on a technique for fault detection based on time-domain identification of transmissibilities, which is neither active nor passive as defined earlier. Instead, this technique takes advantage of freely available and unknown external (ambient) excitation to identify a sensor-to-sensor model (i.e., a transmissibility operator), which is independent of the excitation signal. In the presence of subsequent unknown external excitation, the identified transmissibility is used to compute sensor-to-sensor residuals, which are used to detect and diagnose faults in sensors and system dynamics. The sensor-to-sensor residual is the discrepancy between the predicted sensor output (based on the transmissibility) and the actual measurements.

The ability to take advantage of unknown external excitation along with the fact that the transmissibility is independent of the excitation gives the method flexibility in practice by removing the need for a known or controlled excitation. For example, freely available ambient noise can play a useful role in transmissibility identification. Most importantly, the identified transmissibility is independent of the excitation; this means that the transmissibility identified using one data set can be used for fault detection with a different data set; for both data sets, the external excitation can be completely unknown. This feature is the key benefit of this approach relative to fault-detection methods that require known external excitation. Transmissibilities are applied to fault detection and localization in Refs. [2431]. Note that comparing transmissibility-based fault detection to other fault-detection methods such as Refs. [1820], [32], and [33], which require knowledge of a mathematical model of the underlying system or the excitation signal, is meaningless.

Since transmissibility operators may be noncausal, unstable, and of unknown order, we consider a class of models that can approximate transmissibility operators with these properties. This class of models consists of noncausal finite impulse response (FIR) models based on a truncated Laurent expansion [34]. These models are shown to approximate the Laurent expansion inside the annulus between the asymptotically stable pole of largest modulus and the unstable pole of smallest modulus. By delaying the measured pseudo output relative to the measured pseudo input, the identified finite impulse response model is a noncausal approximation of the transmissibility operator. The causal (backward-shift) part of the Laurent expansion is asymptotically stable since all of its poles are zero, while the noncausal (forward-shift) part of the Laurent expansion captures the unstable and noncausal components of the transmissibility operator. Subspace identification is also used with the measured pseudo input and the delayed measured pseudo output to identify a noncausal state space model.

Since the transmissibility operator has the form of an input–output time-series model, methods developed for ARMAX models are candidates for this application. Some caution is needed, however, since the pseudo input and pseudo output of the transmissibility are both noisy, leading to an errors-in-variables problem with noise on both the input and output signals [3537]. In addition, neither the pseudo input nor the pseudo output signals (irrespective of the noise) can be expected to be white, thus complicating the consistency analysis. Due to the difficulty of the errors-in-variables problem, we compare the one-step prediction error for the estimates of the transmissibility operator obtained using least squares (LS), prediction error methods (PEM), instrumental variables (IV), and subspace identification, and we compare the accuracy of the estimates based on the one-step prediction error.

Transmissibility operators were used in Ref. [38] for rate-gyro health monitoring in aircraft. Moreover, transmissibility operators were used in Ref. [39] for aircraft structural health monitoring. In addition, transmissibility operators were used in Ref. [40] for fault detection in an acoustic system consisting of a drum, two speakers, and four microphones. In the present paper, we extend the results in Ref. [40] by considering an experimental setup consisting of an acoustic system with three speakers and six microphones. Each speaker is an actuator, and each microphone is a sensor that measures the acoustic response at its location. Measurements from the six microphones are used to construct transmissibility operators, which in turn are used to detect and localize changes in the dynamics of the acoustic system or the microphones and by computing the resulting one-step residual.

The paper is organized as follows: In Sec. 2, we derive multi-input, multi-output transmissibility operators. In Sec. 3, we show that transmissibility operators can be noncausal, unstable, and of unknown order and thus noncausal FIR models can be used to approximate transmissibility operators with these properties. In Sec. 4, we use noncausal FIR models with least squares, prediction error methods, instrumental variables, and subspace methods to identify transmissibility operators. In Sec. 5, we use the identified transmissibility operators for fault detection and localization in acoustic systems. Finally, we give conclusions in Sec. 6.

Multi-Input, Multi-Output Transmissibility Operators

We consider the linear system
(1)
(2)
(3)
(4)

where um, p is the number of measurements, m is the number of pseudo inputs, and p − m is the number of pseudo outputs. The coefficient matrices have dimensions An×n,Bn×m,Cim×n,Co(pm)×n,Dim×m, and Do(pm)×m.

The goal is to obtain a relation between yi and yo that is independent of both the initial condition x0 and the input u. Suppose that m = 1 and p=2. Transforming Eqs. (3) and (4) to the Laplace domain yields
(5)
(6)
respectively, and thus
(7)

Note that, if x0 is zero, then û(s) can be canceled in Eq. (7), and ŷo(s) and ŷi(s) are related by a transmissibility that is independent of the input. However, if x0 is not zero, then û(s) cannot be canceled in Eq. (7).

Alternatively, we consider a time-domain approach using the differentiation operator p. Define
(8)
(9)
(10)
where I is the n × n identity matrix and adj denotes the adjugate. Then, the transmissibility operator from yi to yo is the operator [12]
(11)
Note that Eq. (11) is independent of both the initial condition x0 and the input u. As in Ref. [12]
(12)
represents the differential equation
(13)

The transmissibility operator (11) is in continuous time. Henceforth, we assume that measurements of the output signals are obtained in discrete time, and we consider discrete-time transmissibility operators in the forward-shift operator q [41].

Noncausal Finite Impulse Response Approximation of Transmissibility Operators

Expression (11) shows that T(p) contains information about the zeros of the system but not the poles. Therefore, a non-minimum-phase zero in the input channel of a transmissibility operator results in an unstable transmissibility operator. Moreover, if the output channel of a transmissibility operator has more zeros than the input channel, then the transmissibility operator is improper, that is, noncausal. Since this information may not be known in advance, we consider a class of models that can be used to approximate transmissibility operators that may be both unstable and improper.

Finite impulse response models can be used to describe linear asymptotically stable systems [42]. In addition, noncausal FIR models can be used to describe systems that are both noncausal and unstable [34]. A noncausal FIR model, which approximates the Laurent series of an unstable system, involves both positive and negative powers of the Z-transform variable z. The negative powers of z approximate the asymptotically stable part of the plant outside of a disk (that is, inside a punctured plane), whereas the positive powers of z approximate the unstable part of the plant inside a disk. Inside the common region, which is an annulus, the Laurent series represents a noncausal model, as evidenced by the positive powers of z [34]. Noncausal FIR models were also used in Refs. [4345].

Consider the transmissibility operator whose input is yi and whose output is yo. We can write
(14)
where Hi(pm)×m for all i(,) are the coefficients of the Laurent series of T(z) in the annulus of analyticity that contains the unit circle. Let r, d be positive integers and define
(15)
where μ=r+d+1. Let q1 be the backward shift operator and define the noncausal FIR model for the transmissibility (11) as [34]
(16)
Then, the noncausal FIR model output can be defined as [34]
(17)

Identification of Transmissibility Operators Using Noncausal Finite Impulse Response and State Space Models

To identify transmissibility operators that are possibly improper, unstable, and of unknown order, we first use noncausal FIR models with LS, PEM [46], and IV [47].

For each choice of transmissibility coefficients
(18)
it follows that:
(19)
The residual of the transmissibility T(q1,θ¯r,d) at time k is defined to be the one-step prediction error
(20)
The accuracy of θ¯r,d is measured by the performance metric
(21)
where ·2 is the Euclidean norm and +1 is the number of data samples. Then, the least squares estimate θ̂r,d, of θr,d is given by
(22)
where
(23)

We use the Matlab functions pem and iv4 to obtain PEM and IV estimates θ̂r,d, of θr,d, respectively.

It follows from Eq. (20) that the residual of the identified transmissibility T(q1,θ̂r,d,) at time k is given by
(24)
and thus
(25)
For all rkwd, define
(26)
which is the norm of the residual of the data window of size w + 1 starting at time-step k. Expressions (24)(26) measure the accuracy of the transmissibility from yi to yo for the estimate θ̂r,d, of θr,d. The identification data set used to obtain θ̂r,d, is different from the validation data set used to compute Eqs. (24)(26).
For subspace identification, we delay the pseudo output d steps with respect to the pseudo input, and we use the Matlab command n4sid(data,n) to obtain a noncausal state space model of order n. Let θ̂ss,n,d,=(Ân,d,,B̂n,d,,Ĉn,d,,D̂n,d,) be the identified state space model of order n using samples and d steps of delay applied for the pseudo output with respect to the pseudo input. Then, the identified transmissibility operator T(q1,θ̂ss,n,d,) can be represented by the noncausal state space model
(27)
(28)
Therefore, we can write
(29)
and the state space model output can be written as
(30)
The residual of the identified transmissibility T(q1,θ̂ss,n,d,) at time k is defined to be the one-step prediction error
(31)
The accuracy of θ̂ss,n,d, is measured by the performance metric
(32)

where r has the same value as in Eq. (25) in order to perform a fair comparison between Eqs. (25) and (32).

Constructing a meaningful transmissibility operator requires knowledge of the number m of independent external excitation signals acting on the system. Since m may be unknown, we estimate m using the following procedure. Let m̂{1,,p1} and p̂{1,,pm̂}. We identify a transmissibility operator with m̂ pseudo inputs and p̂ pseudo outputs using the methods discussed earlier. For each identified transmissibility operator, we compute the residual using Eq. (24) or (31) and the norm of the residual using Eq. (25) or (32). The estimated number of independent external excitation signals is the value of m̂ at which a sharp drop occurs in the norm of the residual. If a sharp drop is not obvious, then the estimated number of external excitation signals is the smallest value of m̂ for which no sizable improvement is obtained for larger values of m̂. Redundant sensors can then be removed or retained for possible benefit in terms of the accuracy of the identified transmissibility operators. This method will be illustrated in Sec. 5.2.

Application to Health Monitoring in Acoustic Systems

In order to investigate the ability of transmissibility operators to detect changes in the dynamics of an acoustic system, we consider the experimental setup shown in Fig. 1. The setup consists of an acoustic space with three speakers Spk1, Spk2, and Spk3 and six microphones Mic1,,Mic6. Each speaker is an actuator, and each microphone is a sensor that measures the acoustic response at its location. All actuator signals are generated using matlab and sent to the speakers through a data acquisition card. The sampling rate is 1000 Hz.

Fig. 1
Experimental setup. The setup consists of an acoustic space with three speakers Spk1, Spk2, and Spk3 and six microphones Mic1,…,Mic6. Each speaker is an actuator, and each microphone is a sensor that measures the acoustic response at its location.
Fig. 1
Experimental setup. The setup consists of an acoustic space with three speakers Spk1, Spk2, and Spk3 and six microphones Mic1,…,Mic6. Each speaker is an actuator, and each microphone is a sensor that measures the acoustic response at its location.
Close modal

Let u1, u2, and u3 be the measurements of the signals of the speakers Spk1, Spk2, and Spk3, respectively, and let y1,,y6 be the measurements obtained by the sensors Mic1,,Mic6, respectively. We assume that data are available for 1k20,000.

Identification of Transmissibility Operators Under Healthy Conditions.

To identify transmissibility operators, we delay the pseudo output d steps with respect to the pseudo input and perform the identification using the pseudo input and the delayed pseudo output. We use LS, PEM, and IV with a noncausal FIR model with r = 24, d=25, and the first =6000 samples to obtain the identified transmissibilities. The least squares estimate is obtained using Eq. (22), where the PEM and IV estimates are obtained using the Matlab commands pem(data,'nb',(r + d + 1)* ones(1, i),'nc' , r + d + 1) and iv4(data,'nb',(r + d + 1)*ones(1,i)), respectively, where i is the number of pseudo inputs.

For subspace identification, we delay the pseudo output d steps with respect to the pseudo input, and we use the Matlab command n4sid(data,n) and the first =6000 samples to obtain the identified noncausal state space model of order n. Since an nth-order infinite impulse response model has 2n+2 parameters and an nth-order FIR model has n parameters, we compare an infinite impulse response model of order n to an FIR model of order 2n+2. Since the order of the noncausal FIR model is r+d+1, for subspace identification, we use the model order n=(r+d1)/2=24.

Suppose that Spk1 is driven with a realization of band-limited white noise with a bandwidth of 500 Hz and Spk2 and Spk3 are not operating. Figure 2 shows the estimated Markov parameters θ̂r,d, of T(q1,θr,d) from the pseudo input y1 to the pseudo output y6 obtained using least squares for two different runs of the experiment. Figure 3 shows y6 and the computed one-step prediction ŷ6=T(q1,θ̂r,d,)y1 for 15,000k15,300, that is, for t[15,15.3] s.

Fig. 2
For the acoustic system shown in Fig. 1 operating under healthy conditions, Spk1 is driven with a realization of bandlimited white noise with a bandwidth of 500 Hz and Spk2 and Spk3 are not operating. This plot shows the estimated Markov parameters θ̂r,d,ℓ of T(q−1,θr,d) from the pseudo input y1 to the pseudo output y6 for two different runs of the experiment.
Fig. 2
For the acoustic system shown in Fig. 1 operating under healthy conditions, Spk1 is driven with a realization of bandlimited white noise with a bandwidth of 500 Hz and Spk2 and Spk3 are not operating. This plot shows the estimated Markov parameters θ̂r,d,ℓ of T(q−1,θr,d) from the pseudo input y1 to the pseudo output y6 for two different runs of the experiment.
Close modal
Fig. 3
For the acoustic system shown in Fig. 1 operating under healthy conditions, Spk1 is driven with a realization of bandlimited white noise with a bandwidth of 500 Hz. This plot shows the measurements of y6 and the computed one-step prediction ŷ6=T(q−1,θ̂r,d,ℓ)y1, where θ̂r,d,ℓ is obtained from run 1 shown in Fig. 2.
Fig. 3
For the acoustic system shown in Fig. 1 operating under healthy conditions, Spk1 is driven with a realization of bandlimited white noise with a bandwidth of 500 Hz. This plot shows the measurements of y6 and the computed one-step prediction ŷ6=T(q−1,θ̂r,d,ℓ)y1, where θ̂r,d,ℓ is obtained from run 1 shown in Fig. 2.
Close modal

Next, suppose that Spk1 and Spk2 are driven with realizations of bandlimited white noise with a bandwidth of 500 Hz and Spk3 is not operating. Figure 4 shows the entries of the estimated Markov parameters θ̂r,d, of T(q1,θr,d) from each pseudo input y1 and y3 to the pseudo output y6 obtained using least squares for two different runs of the experiment. Figure 5 shows y6 and the computed one-step prediction ŷ6=T(q1,θ̂r,d,)[y1y3]T for 15,000k15,300, that is, for t[15,15.3] s.

Fig. 4
For the acoustic system shown in Fig. 1 operating under healthy conditions, Spk1 and Spk2 are driven with realizations of band-limited white noise with a bandwidth of 500 Hz and Spk3 is not operating. This plot shows the entries of the estimated Markov parameters θ̂r,d,ℓ of T(q−1,θr,d) from each pseudo input y1 and y3 to the pseudo output y6 for two different runs of the experiment.
Fig. 4
For the acoustic system shown in Fig. 1 operating under healthy conditions, Spk1 and Spk2 are driven with realizations of band-limited white noise with a bandwidth of 500 Hz and Spk3 is not operating. This plot shows the entries of the estimated Markov parameters θ̂r,d,ℓ of T(q−1,θr,d) from each pseudo input y1 and y3 to the pseudo output y6 for two different runs of the experiment.
Close modal
Fig. 5
For the acoustic system shown in Fig. 1 operating under healthy conditions, Spk1 and Spk2 are driven with realizations of band-limited white noise with a bandwidth of 500 Hz. This plot shows the measurements of y6 and the computed one-step prediction ŷ6=T(q−1,θ̂r,d,ℓ)[y1  y3]T, where θ̂r,d,ℓ is obtained from run 1 shown in Fig. 4.
Fig. 5
For the acoustic system shown in Fig. 1 operating under healthy conditions, Spk1 and Spk2 are driven with realizations of band-limited white noise with a bandwidth of 500 Hz. This plot shows the measurements of y6 and the computed one-step prediction ŷ6=T(q−1,θ̂r,d,ℓ)[y1  y3]T, where θ̂r,d,ℓ is obtained from run 1 shown in Fig. 4.
Close modal

Next, suppose that Spk1, Spk2, and Spk3 are driven with realizations of bandlimited white noise with a bandwidth of 500 Hz. Figure 6 shows the entries of the estimated Markov parameters θ̂r,d, of T(q1,θr,d) from each pseudo input y1, y3, and y5 to the pseudo output y6 obtained using least squares for two different runs of the experiment. Figure 7 shows y6 and the computed one-step prediction ŷ6T(q1,θ̂r,d,)[y1y3y5]T for 15,000k15,300, that is, for t[15,15.3] s.

Fig. 6
Spk1, Spk2, and Spk3 are driven with realizations of bandlimited white noise with a bandwidth of 500 Hz. The plot shows the entries of the estimated Markov parameters θ̂r,d,ℓ of T(q−1,θr,d) from each pseudo input y1, y3, and y5 to the pseudo output y6 for two different runs of the experiment.
Fig. 6
Spk1, Spk2, and Spk3 are driven with realizations of bandlimited white noise with a bandwidth of 500 Hz. The plot shows the entries of the estimated Markov parameters θ̂r,d,ℓ of T(q−1,θr,d) from each pseudo input y1, y3, and y5 to the pseudo output y6 for two different runs of the experiment.
Close modal
Fig. 7
For the acoustic system shown in Fig. 1 operating under healthy conditions, Spk1, Spk2, and Spk3 are driven with realizations of bandlimited white noise with a bandwidth of 500 Hz. This plot shows the measurements of y6 and the computed one-step prediction ŷ6=T(q−1,θ̂r,d,ℓ)[y1  y3  y5]T, where θ̂r,d,ℓ is obtained from run 1 shown in Fig. 6.
Fig. 7
For the acoustic system shown in Fig. 1 operating under healthy conditions, Spk1, Spk2, and Spk3 are driven with realizations of bandlimited white noise with a bandwidth of 500 Hz. This plot shows the measurements of y6 and the computed one-step prediction ŷ6=T(q−1,θ̂r,d,ℓ)[y1  y3  y5]T, where θ̂r,d,ℓ is obtained from run 1 shown in Fig. 6.
Close modal
Next, suppose that Spk1, Spk2, and Spk3 are driven with the harmonic signals
(33)
(34)
(35)
respectively. Figure 8 shows y6 and the computed one-step prediction ŷ6=T(q1,θ̂r,d,)[y1y3y5]T for 15,000k15,300, that is, for t[15,15.3] s, where θ̂r,d, is the least squares estimate obtained from run 1 shown in Fig. 6 using broadband excitation. Figure 8 confirms that the identified transmissibility obtained under one type of excitation signal can be used under another type of excitation signal. This is advantageous for fault detection, where a transmissibility is identified under one set of conditions and used under a different set of conditions.
Fig. 8
For the acoustic system shown in Fig. 1 operating under healthy conditions, Spk1, Spk2, and Spk3 are driven with the harmonic signals (33)–(35). This plot shows the measurements of y6 and the computed one-step prediction ŷ6=T(q−1,θ̂r,d,ℓ)[y1  y3  y5]T, where θ̂r,d,ℓ is obtained from run 1 shown in Fig. 6. This figure confirms that the identified transmissibility obtained under one type of excitation signal can be used under another type of excitation signal. This is advantageous for fault detection, where transmissibilities are identified under one set of conditions and used under a different set of conditions.
Fig. 8
For the acoustic system shown in Fig. 1 operating under healthy conditions, Spk1, Spk2, and Spk3 are driven with the harmonic signals (33)–(35). This plot shows the measurements of y6 and the computed one-step prediction ŷ6=T(q−1,θ̂r,d,ℓ)[y1  y3  y5]T, where θ̂r,d,ℓ is obtained from run 1 shown in Fig. 6. This figure confirms that the identified transmissibility obtained under one type of excitation signal can be used under another type of excitation signal. This is advantageous for fault detection, where transmissibilities are identified under one set of conditions and used under a different set of conditions.
Close modal

Estimating the Number of Inputs Acting on the System.

Suppose that the system shown in Fig. 1 is operating under healthy conditions, and suppose that Spk1 is driven with a realization of bandlimited white noise with a bandwidth of 500 Hz and Spk2 and Spk3 are not operating. Figure 9 shows the norm of the residual for each identified transmissibility operator whose pseudo input is Yi=[y1yi]T, for i=1,,5, and whose pseudo output is y6 obtained using LS, PEM, IV, and subspace methods. Note from Fig. 9 that the improved residual obtained by using 2, 3, 4, or 5 pseudo inputs is not significant, which correctly suggests that there is one independent external excitation signal acting on the system.

Fig. 9
For the acoustic system shown in Fig. 1 operating under healthy conditions, Spk1 is driven with a realization of bandlimited white noise with a bandwidth of 500 Hz and Spk2 and Spk3 are not operating. This plot shows the norm of the residual for the identified transmissibility operators with 1,…,5 pseudo inputs. Note that the benefits produced by using 2, 3, 4, or 5 pseudo inputs are not significant, which correctly suggests that the number of independent external excitation signals acting on the systems is 1.
Fig. 9
For the acoustic system shown in Fig. 1 operating under healthy conditions, Spk1 is driven with a realization of bandlimited white noise with a bandwidth of 500 Hz and Spk2 and Spk3 are not operating. This plot shows the norm of the residual for the identified transmissibility operators with 1,…,5 pseudo inputs. Note that the benefits produced by using 2, 3, 4, or 5 pseudo inputs are not significant, which correctly suggests that the number of independent external excitation signals acting on the systems is 1.
Close modal

Next, suppose that the system shown in Fig. 1 is operating under healthy conditions, and suppose that both Spk1 and Spk2 are driven with realizations of bandlimited white noise with a bandwidth of 500 Hz, and Spk3 is not operating. Figure 10 shows the norm of the residual for each identified transmissibility operator whose pseudo input is Yi for i=1,,5, and whose pseudo output is y6 obtained using LS, PEM, IV, and subspace methods. Figure 10 shows that the identified transmissibility operator with two pseudo inputs yields significantly lower residual than the identified transmissibility operators with one pseudo input. However, the improved residuals obtained by using 3, 4, or 5 pseudo inputs are not significant, which correctly suggests that the number of independent external excitation signals acting on the systems is two.

Fig. 10
For the acoustic system shown in Fig. 1 operating under healthy conditions, Spk1 and Spk2 are driven with realizations of bandlimited white noise with a bandwidth of 500 Hz and Spk3 is not operating. This plot shows norm of the residual for the identified transmissibility operators with 1,…,5 pseudo inputs. Note that the benefits produced by using two pseudo inputs are significant, but the benefits produced by using 3, 4, or 5 pseudo inputs are not significant, which correctly suggests that the number of independent external excitation signals acting on the systems is 2.
Fig. 10
For the acoustic system shown in Fig. 1 operating under healthy conditions, Spk1 and Spk2 are driven with realizations of bandlimited white noise with a bandwidth of 500 Hz and Spk3 is not operating. This plot shows norm of the residual for the identified transmissibility operators with 1,…,5 pseudo inputs. Note that the benefits produced by using two pseudo inputs are significant, but the benefits produced by using 3, 4, or 5 pseudo inputs are not significant, which correctly suggests that the number of independent external excitation signals acting on the systems is 2.
Close modal

Next, suppose that the system shown in Fig. 1 is operating under healthy conditions, and suppose that Spk1, Spk2, and Spk3 are driven with realizations of bandlimited white noise with a bandwidth of 500 Hz. Figure 11 shows the norm of the residual for the identified transmissibility operator whose pseudo input is Yi for i=1,,5, and whose pseudo output is y6 obtained using LS, PEM, IV, and subspace methods. Figure 11 shows that the identified transmissibility operators with three pseudo inputs yield significantly lower residual than the identified transmissibility operators with one and two pseudo inputs. However, the improved residual obtained by using four or five pseudo input is not significant, which correctly suggests that the number of independent external excitation signals acting on the systems is three.

Fig. 11
For the acoustic system shown in Fig. 1 operating under healthy conditions, Spk1, Spk2, and Spk3 are driven with realizations of band-limited white noise with a bandwidth of 500 Hz. This plot shows norm of the residual for the identified transmissibility operators with 1,…,5 pseudo inputs. Note that the benefits produced by using two or three pseudo inputs are significant, but the benefits produced by using four or five pseudo inputs are not significant, which correctly suggests that the number of independent external excitation signals acting on the systems is 3.
Fig. 11
For the acoustic system shown in Fig. 1 operating under healthy conditions, Spk1, Spk2, and Spk3 are driven with realizations of band-limited white noise with a bandwidth of 500 Hz. This plot shows norm of the residual for the identified transmissibility operators with 1,…,5 pseudo inputs. Note that the benefits produced by using two or three pseudo inputs are significant, but the benefits produced by using four or five pseudo inputs are not significant, which correctly suggests that the number of independent external excitation signals acting on the systems is 3.
Close modal

Figure 12 shows the norm of the residuals for the identified transmissibility operators obtained using least squares with 1,,5 pseudo inputs for the case of one, two, or three speakers driven with realizations of bandlimited white noise with a bandwidth of 500 Hz. Figure 12 shows that, in order to reduce the residuals, the number of pseudo inputs has to be greater than or equal to the number of independent inputs acting on the system.

Fig. 12
For the acoustic system shown in Fig. 1 operating under healthy conditions, this plot shows the norm of the residuals for the identified transmissibility operators obtained using LS with 1,…,5 pseudo inputs for the case of 1, 2, or 3 speakers driven with realizations of bandlimited white noise with a bandwidth of 500 Hz. This plot shows that to reduce the residuals, the number of pseudo inputs has to be greater than or equal to the number of independent inputs acting on the system.
Fig. 12
For the acoustic system shown in Fig. 1 operating under healthy conditions, this plot shows the norm of the residuals for the identified transmissibility operators obtained using LS with 1,…,5 pseudo inputs for the case of 1, 2, or 3 speakers driven with realizations of bandlimited white noise with a bandwidth of 500 Hz. This plot shows that to reduce the residuals, the number of pseudo inputs has to be greater than or equal to the number of independent inputs acting on the system.
Close modal

Health Monitoring Using Transmissibility Operators

System Health Monitoring.

To emulate change in the dynamics of the acoustic system, we remove a blanket that covers the acoustic space during the experiment. For structural health monitoring, we use the identified transmissibility T(q1,θ̂r,d,) whose pseudo input is yi=[y1y3y5]T and whose pseudo output is yo=y6 and whose Markov parameters are obtained using least squares from run 1 shown in Fig. 6.

Suppose that Spk1, Spk2, and Spk3 are operating simultaneously and are driven with a band-limited white noise with a bandwidth of 500 Hz. At approximately t = 11 s, we remove the blanket that covers the acoustic system. Figure 13 shows E(k|θ̂r,d,,w) for T(q1,θ̂r,d,), where w = 500 steps. Note from Fig. 13 the change in E(k|θ̂r,d,,w) at approximately t = 11 due to the change in the dynamics of the system.

Fig. 13
For the acoustic system shown in Fig. 1, Spk1, Spk2, and Spk3 are driven with a band-limited white noise with a bandwidth of 500 Hz. At approximately t = 11 s, the blanket that covers the acoustic system is removed. This plot shows E(k|θ̂r,d,ℓ,w) for T(q−1,θ̂r,d,ℓ), where w = 500 steps and θ̂r,d,ℓ is the LS estimate obtained from run 1 shown in Fig. 6 using broadband excitation. Note the change in E(k|θ̂r,d,ℓ,w) at approximately t = 11 s due to the change in the dynamics of the acoustic system.
Fig. 13
For the acoustic system shown in Fig. 1, Spk1, Spk2, and Spk3 are driven with a band-limited white noise with a bandwidth of 500 Hz. At approximately t = 11 s, the blanket that covers the acoustic system is removed. This plot shows E(k|θ̂r,d,ℓ,w) for T(q−1,θ̂r,d,ℓ), where w = 500 steps and θ̂r,d,ℓ is the LS estimate obtained from run 1 shown in Fig. 6 using broadband excitation. Note the change in E(k|θ̂r,d,ℓ,w) at approximately t = 11 s due to the change in the dynamics of the acoustic system.
Close modal

Next, suppose that Spk1, Spk2, and Spk3 are operating simultaneously and are driven with the harmonic signals (33)–(35). At approximately t = 11 s, we remove the blanket that covers the acoustic system. Figure 14 shows E(k|θ̂r,d,,w) for T(q1,θ̂r,d,), where w = 500 steps. Note from Fig. 14 the change in E(k|θ̂r,d,,w) at approximately t = 11 s due to the change in the dynamics of the system.

Fig. 14
For the acoustic system shown in Fig. 1, u1,u2,u3 are as shown in Eqs. (33)–(35). At approximately t = 11 s, the blanket that covers the acoustic system is removed. This plot shows E(k|θ̂r,d,ℓ,w) for T(q−1,θ̂r,d,ℓ), where w = 500 steps and θ̂r,d,ℓ is the LS estimate obtained from run 1 shown in Fig. 6 using broadband excitation. Note the change in E(k|θ̂r,d,ℓ,w) at approximately t = 11 s due to the change in the dynamics of the acoustic system.
Fig. 14
For the acoustic system shown in Fig. 1, u1,u2,u3 are as shown in Eqs. (33)–(35). At approximately t = 11 s, the blanket that covers the acoustic system is removed. This plot shows E(k|θ̂r,d,ℓ,w) for T(q−1,θ̂r,d,ℓ), where w = 500 steps and θ̂r,d,ℓ is the LS estimate obtained from run 1 shown in Fig. 6 using broadband excitation. Note the change in E(k|θ̂r,d,ℓ,w) at approximately t = 11 s due to the change in the dynamics of the acoustic system.
Close modal

Sensor Health Monitoring.

For sensor health monitoring, the level of the residual for a transmissibility changes as one of the sensors that are used to construct the transmissibility becomes faulty. We introduce faults in the microphones by modifying the low-pass analog filter that the microphone signal passes through before going to the dSPACE system.

Suppose that Spk1, Spk2, and Spk3 are operating simultaneously and are driven with a band-limited white noise with a bandwidth of 500 Hz. Let T(q1,θ̂r,d,), be the identified transmissibility whose pseudo input is yi=[y1y2y3]T and whose pseudo output is yo=y6 obtained using least squares with a noncausal FIR model with r = 24 and d = 25. At approximately t = 10 s, a fault occurs to Mic2. Figure 15 shows a plot of E(k|θ̂r,d,,w) for T(q1,θ̂r,d,), where w = 500 steps. Note the change in E(k|θ̂r,d,,w) at approximately t = 10 s due to the faulty microphone.

Fig. 15
For the acoustic system shown in Fig. 1, Spk1, Spk2, and Spk3 are driven with a band-limited white noise with a bandwidth of 500 Hz. At approximately t = 10 s, a fault occurs in Mic2. This plot shows E(k|θ̂r,d,ℓ,w) for T(q−1,θ̂r,d,ℓ), where w = 500 steps. Note the change in E(k|θ̂r,d,ℓ,w) at approximately t = 10 s due to the faulty microphone.
Fig. 15
For the acoustic system shown in Fig. 1, Spk1, Spk2, and Spk3 are driven with a band-limited white noise with a bandwidth of 500 Hz. At approximately t = 10 s, a fault occurs in Mic2. This plot shows E(k|θ̂r,d,ℓ,w) for T(q−1,θ̂r,d,ℓ), where w = 500 steps. Note the change in E(k|θ̂r,d,ℓ,w) at approximately t = 10 s due to the faulty microphone.
Close modal

Next, suppose that u1,u2,u3 are as shown in Eqs. (33)(35). At approximately t = 10 s, a fault occurs to Mic3. Figure 16 shows a plot of E(k|θ̂r,d,,w), where w = 500 steps, for the identified transmissibility T(q1,θ̂r,d,) obtained by driving the speakers with white excitations. Note the change in E(k|θ̂r,d,,w) at approximately t = 10 s due to the faulty microphone.

Fig. 16
For the acoustic system shown in Fig. 1 with u1,…,u3 are as shown in Eqs. (33)–(35). At approximately t = 10 s, a fault occurs in Mic3. This plot shows E(k|θ̂r,d,ℓ,w) for T(q−1,θ̂r,d,ℓ), where w = 500 steps. Note the change in E(k|θ̂r,d,ℓ,w) at approximately t = 10 s due to the faulty microphone.
Fig. 16
For the acoustic system shown in Fig. 1 with u1,…,u3 are as shown in Eqs. (33)–(35). At approximately t = 10 s, a fault occurs in Mic3. This plot shows E(k|θ̂r,d,ℓ,w) for T(q−1,θ̂r,d,ℓ), where w = 500 steps. Note the change in E(k|θ̂r,d,ℓ,w) at approximately t = 10 s due to the faulty microphone.
Close modal

Fault Localization.

Consider the transmissibilities T1,,T6 whose pseudo inputs and pseudo outputs are as shown in Table 1. We assume that, during the experiment, at most one microphone is faulty. Figure 17 shows an algorithm to localize the fault whether it has occurred in the acoustic system or in one of the microphones.

Fig. 17
Fault localization algorithm. This algorithm is consistent with the transmissibility operators as defined in Table 1.
Fig. 17
Fault localization algorithm. This algorithm is consistent with the transmissibility operators as defined in Table 1.
Close modal
Table 1

Transmissibilities T1,,T6 with the pseudo inputs and the pseudo outputs as shown in this table are used in the fault localization algorithm shown in Fig. 17 

yiyo
T1[y1y2y3y4y5]Ty6
T2[y1y2y3]Ty4
T3[y2y3y4]Ty5
T4[y1y2y3]Ty5
T5[y1y3y4]Ty5
T6[y1y4y5]Ty6
yiyo
T1[y1y2y3y4y5]Ty6
T2[y1y2y3]Ty4
T3[y2y3y4]Ty5
T4[y1y2y3]Ty5
T5[y1y3y4]Ty5
T6[y1y4y5]Ty6

Suppose that only Spk1 is operating and is driven with a band-limited white noise with a bandwidth of 500 Hz. We introduce a change in the dynamics of the acoustic system by removing the blanket at approximately t = 10 s. Figure 18 shows a plot of E(k|θ̂r,d,,w) for the identified transmissibilities Ti(q1,θ̂r,d,) of Ti for i=1,,6. Note from Fig. 18 that a fault has been detected by all transmissibilities, and thus, using Fig. 17, we correctly conclude that the fault is due to the change in the dynamics of the acoustic system.

Fig. 18
For the acoustic system shown in Fig. 1, Spk1, Spk2, and Spk3 are realizations of bandlimited white noise with a bandwidth of 500 Hz. At approximately t = 10 s, the blanket that covers the acoustic system is removed. This plot shows E(k|θ̂r,d,ℓ,w) of the identified transmissibilities Ti(q−1,θ̂r,d,ℓ) of Ti, for i=1,…,6, where w = 500 steps. Note the change in E(k|θ̂r,d,ℓ,w) for all transmissibilities at approximately t = 10 s due to the change in the dynamics of the system. Using Fig. 17, we correctly conclude that the fault is in the system.
Fig. 18
For the acoustic system shown in Fig. 1, Spk1, Spk2, and Spk3 are realizations of bandlimited white noise with a bandwidth of 500 Hz. At approximately t = 10 s, the blanket that covers the acoustic system is removed. This plot shows E(k|θ̂r,d,ℓ,w) of the identified transmissibilities Ti(q−1,θ̂r,d,ℓ) of Ti, for i=1,…,6, where w = 500 steps. Note the change in E(k|θ̂r,d,ℓ,w) for all transmissibilities at approximately t = 10 s due to the change in the dynamics of the system. Using Fig. 17, we correctly conclude that the fault is in the system.
Close modal

Next, suppose that u1,u2,u3 are as shown in Eqs. (33)(35). We introduce a fault in Mic2 at approximately t = 10 s. Figure 19 shows a plot of E(k|θ̂r,d,,w) for the identified transmissibilities Ti(q1,θ̂r,d,) of Ti for i=1,,6. Note from Fig. 19 that a fault is detected by all transmissibilities except T5 and T6, and thus, using Fig. 17, we correctly conclude that the fault is in Mic2.

Fig. 19
For the acoustic system shown in Fig. 1, u1,u2,u3 are as shown in Eqs. (33)–(35). At approximately t = 10 s, a fault occurs in Mic2. This plot shows E(k|θ̂r,d,ℓ,w) for the identified transmissibilities Ti(q−1,θ̂r,d,ℓ) of Ti, for i=1,…,6, where w = 500 steps. Note the change in E(k|θ̂r,d,ℓ,w) of all transmissibilities except T5 and T6 at approximately t = 10 s due to the faulty microphone. Using Fig. 17, we correctly conclude that Mic2 is faulty.
Fig. 19
For the acoustic system shown in Fig. 1, u1,u2,u3 are as shown in Eqs. (33)–(35). At approximately t = 10 s, a fault occurs in Mic2. This plot shows E(k|θ̂r,d,ℓ,w) for the identified transmissibilities Ti(q−1,θ̂r,d,ℓ) of Ti, for i=1,…,6, where w = 500 steps. Note the change in E(k|θ̂r,d,ℓ,w) of all transmissibilities except T5 and T6 at approximately t = 10 s due to the faulty microphone. Using Fig. 17, we correctly conclude that Mic2 is faulty.
Close modal

Next, suppose that u1,u2,u3 are as shown in Eqs. (33)(35). We introduce a fault in Mic3 at approximately t = 10 s. Figure 20 shows a plot of E(k|θ̂r,d,,w) for the identified transmissibilities Ti(q1,θ̂r,d,) of Ti for i=1,,6. Note from Fig. 20 that a fault is detected by all transmissibilities except T6, and thus, using Fig. 17, we correctly conclude that the fault is in Mic3.

Fig. 20
For the acoustic system shown in Fig. 1, u1,u2,u3 are as shown in Eqs. (33)–(35). At approximately t = 10 s, a fault occurs in Mic3. This plot shows E(k|θ̂r,d,ℓ,w) for the identified transmissibilities Ti(q−1,θ̂r,d,ℓ) of Ti, for i=1,…,6, where w = 500 steps. Note the change in E(k|θ̂r,d,ℓ,w) of all transmissibilities except T6 at approximately t = 10 s due to the faulty microphone. Using Fig. 17, we correctly conclude that Mic3 is faulty.
Fig. 20
For the acoustic system shown in Fig. 1, u1,u2,u3 are as shown in Eqs. (33)–(35). At approximately t = 10 s, a fault occurs in Mic3. This plot shows E(k|θ̂r,d,ℓ,w) for the identified transmissibilities Ti(q−1,θ̂r,d,ℓ) of Ti, for i=1,…,6, where w = 500 steps. Note the change in E(k|θ̂r,d,ℓ,w) of all transmissibilities except T6 at approximately t = 10 s due to the faulty microphone. Using Fig. 17, we correctly conclude that Mic3 is faulty.
Close modal

Next, suppose that u1,u2,u3 are as shown in Eqs. (33)(35). We introduce a fault in Mic5 at approximately t = 10 s. Figure 21 shows a plot of E(k|θ̂r,d,,w) for the identified transmissibilities Ti(q1,θ̂r,d,) of Ti for i=1,,6. Note from Fig. 21 that a fault has been detected by all transmissibilities except T2, and thus, using Fig. 17, we correctly conclude that the fault is in Mic5.

Fig. 21
For the acoustic system shown in Fig. 1, u1,u2,u3 are as shown in Eqs. (33)–(35). At approximately t = 10 s, a fault occurs in Mic5. This plot shows E(k|θ̂r,d,ℓ,w) for the identified transmissibilities Ti(q−1,θ̂r,d,ℓ) of Ti, for i=1,…,6, where w = 500 steps. Note the change in E(k|θ̂r,d,ℓ,w) of all transmissibilities except T2 at approximately t = 10 s due to the faulty microphone. Using Fig. 17, we correctly conclude that Mic5 is faulty.
Fig. 21
For the acoustic system shown in Fig. 1, u1,u2,u3 are as shown in Eqs. (33)–(35). At approximately t = 10 s, a fault occurs in Mic5. This plot shows E(k|θ̂r,d,ℓ,w) for the identified transmissibilities Ti(q−1,θ̂r,d,ℓ) of Ti, for i=1,…,6, where w = 500 steps. Note the change in E(k|θ̂r,d,ℓ,w) of all transmissibilities except T2 at approximately t = 10 s due to the faulty microphone. Using Fig. 17, we correctly conclude that Mic5 is faulty.
Close modal

Conclusions

A transmissibility operator is a relationship between pairs or sets of sensors that is independent of the excitation signal and the initial conditions of the underlying system. Constructing a transmissibility operator requires knowledge of the number of external excitation signals acting on the system, which as we showed can be estimated from the sensor measurements. A transmissibility operator can be noncausal, unstable, and of unknown order and thus a noncausal FIR model can be used to identify transmissibility operators. This paper considered an application of transmissibility operators for fault detection and localization in acoustic systems. The experimental setup we considered consists of an acoustic system with three speakers and six microphones. Measurements from the six microphones were used with least squares, prediction error methods, instrumental variables, and subspace methods to identify transmissibility operators. The identified transmissibility operators were used to detect and localize changes in the dynamics of the acoustic system and the microphones.

Funding Data

  • National Aeronautics and Space Administration (Grant No. NNX14AJ55A).

  • National Science Foundation (Grant No. CMMI 1536834).

References

1.
Aljanaideh
,
K. F.
, and
Bernstein
,
D. S.
,
2015
, “
Time-Domain Analysis of Motion Transmissibilities in Force-Driven and Displacement-Driven Structures
,”
J. Sound Vib.
,
347
, pp.
169
183
.
2.
Ungar
,
E. E.
,
1991
, “
Equality of Force and Motion Transmissibilities
,”
J. Acoust. Soc. Am.
,
90
(
1
), pp.
596
597
.
3.
de Silva
,
C. W.
,
2007
,
Vibration: Fundamentals and Practice
,
CRC Press
,
Boca Raton, FL
.
4.
Devriendt
,
C.
,
De Sitter
,
G.
, and
Guillaume
,
P.
,
2010
, “
An Operational Modal Analysis Approach Based on Parametrically Identified Multivariable Transmissibilities
,”
Mech. Syst. Signal Process.
,
24
(
5
), pp.
1250
1259
.
5.
Ribeiro
,
A.
,
Maia
,
N.
, and
Silva
,
J.
,
1999
, “
Experimental Evaluation of the Transmissibility Matrix
,”
International Modal Analysis Conference
, Kissimmee, FL, Feb. 8–11, pp.
1126
1129
.https://www.researchgate.net/publication/253191116_Experimental_Evaluation_of_the_Transmissibility_Matrix
6.
Maia
,
N.
,
Urgueira
,
A.
, and
Almeida
,
R.
,
2011
, “
Whys and Wherefores of Transmissibility
,”
Vibration Analysis and Control
,
F.
Beltran-Carbajal
, ed., pp.
197
216
.
7.
Devriendt
,
C.
,
Presezniak
,
F.
,
De Sitter
,
G.
,
Vanbrabant
,
K.
,
De Troyer
,
T.
,
Vanlanduit
,
S.
, and
Guillaume
,
P.
,
2010
, “
Structural Health Monitoring in Changing Operational Conditions Using Tranmissibility Measurements
,”
Shock Vib.
,
17
(
4
), pp.
651
675
.
8.
Urgueira
,
A. P.
,
Almeida
,
R. A.
, and
Maia
,
N. M.
,
2011
, “
On the Use of the Transmissibility Concept for the Evaluation of Frequency Response Functions
,”
Mech. Syst. Signal Process.
,
25
(
3
), pp.
940
951
.
9.
Ribeiro
,
A.
,
Silva
,
J.
, and
Maia
,
N.
,
2000
, “
On the Generalization of the Transmissibility Concept
,”
Mech. Syst. Signal Process.
,
14
(
1
), pp.
29
35
.
10.
Brzezinski
,
A. J.
,
Kukreja
,
S. L.
,
Ni
,
J.
, and
Bernstein
,
D. S.
,
2010
, “
Sensor-Only Fault Detection Using Pseudo Transfer Function Identification
,”
American Control Conference
(
ACC
), Baltimore, MD, June 30–July 2, pp.
5433
5438
.
11.
Brzezinski
,
A. J.
,
Kukreja
,
S. L.
,
Ni
,
J.
, and
Bernstein
,
D. S.
,
2011
, “
Identification of Sensor-Only MIMO Pseudo Transfer Functions
,”
Conference on Decision and Control
(
CDC
), Orlando, FL, Dec. 12–15, pp.
1698
1703
.
12.
Aljanaideh
,
K. F.
, and
Bernstein
,
D. S.
,
2015
, “
Time-Domain Analysis of Sensor-to-Sensor Transmissibility Operators
,”
Automatica
,
53
, pp.
312
319
.
13.
Aljanaideh
,
K. F.
, and
Bernstein
,
D. S.
,
2017
, “
A Behavioral Equation Framework for Time-Domain Transmissibilities
,”
Automatica
,
78
, pp.
20
24
.
14.
Hwang
,
I.
,
Kim
,
S.
,
Kim
,
Y.
, and
Seah
,
C. E.
,
2010
, “
A Survey of Fault Detection, Isolation, and Reconfiguration Methods
,”
IEEE Trans. Control Syst. Technol.
,
18
(
3
), pp.
636
653
.
15.
Isermann
,
R.
,
1984
, “
Process Fault Detection Based on Modeling and Estimation Methods—A Survey
,”
Automatica
,
20
(
4
), pp.
387
404
.
16.
Isermann
,
R.
,
2006
,
Fault-Diagnosis Systems
,
Springer
,
New York
.
17.
Isermann
,
R.
,
2011
,
Fault-Diagnosis Applications: Model-Based Condition Monitoring: Actuators, Drives, Machinery, Plants, Sensors, and Fault-Tolerant Systems
,
Springer
,
New York
.
18.
Rajamani
,
R.
, and
Ganguli
,
A.
,
2004
, “
Sensor Fault Diagnostics for a Class of Non-Linear Systems Using Linear Matrix Inequalities
,”
Int. J. Control
,
77
(
10
), pp.
920
930
.
19.
Frank
,
P. M.
,
1990
, “
Fault Diagnosis in Dynamic Systems Using Analytical and Knowledge-Based Redundancy: A Survey and Some New Results
,”
Automatica
,
26
(
3
), pp.
459
474
.
20.
Chow
,
E.
, and
Willsky
,
A. S.
,
1984
, “
Analytical Redundancy and the Design of Robust Failure Detection Systems
,”
IEEE Trans. Autom. Control
,
29
(
7
), pp.
603
614
.
21.
Martin
,
K. F.
,
1994
, “
A Review by Discussion of Condition Monitoring and Fault Diagnosis in Machine Tools
,”
Int. J. Mach. Tools Manuf.
,
34
(
4
), pp.
527
551
.
22.
Kothamasu
,
R.
,
Huang
,
S. H.
, and
VerDuin
,
W. H.
,
2006
, “
System Health Monitoring and Prognostics—A Review of Current Paradigms and Practices
,”
Int. J. Adv. Manuf. Technol.
,
28
(
9–10
), pp.
1012
1024
.
23.
Yan
,
R.
, and
Gao
,
R. X.
,
2007
, “
Approximate Entropy as a Diagnostic Tool for Machine Health Monitoring
,”
Mech. Syst. Signal Process.
,
21
(
2
), pp.
824
839
.
24.
Chesné
,
S.
, and
Deraemaeker
,
A.
,
2013
, “
Damage Localization Using Transmissibility Functions: A Critical Review
,”
Mech. Syst. Signal Process.
,
38
(
2
), pp.
569
584
.
25.
Worden
,
K.
,
1997
, “
Structural Fault Detection Using a Novelty Measure
,”
J. Sound Vib.
,
201
(
1
), pp.
85
101
.
26.
Johnson
,
T. J.
, and
Adams
,
D. E.
,
2002
, “
Transmissibility as a Differential Indicator of Structural Damage
,”
ASME J. Vib. Acoust.
,
124
(
4
), pp.
634
641
.
27.
Maia
,
N. M.
,
Almeida
,
R. A.
,
Urgueira
,
A. P.
, and
Sampaio
,
R. P.
,
2011
, “
Damage Detection and Quantification Using Transmissibility
,”
Mech. Syst. Signal Process.
,
25
(
7
), pp.
2475
2483
.
28.
Lang
,
Z.
,
Park
,
G.
,
Farrar
,
C.
,
Todd
,
M.
,
Mao
,
Z.
,
Zhao
,
L.
, and
Worden
,
K.
,
2011
, “
Transmissibility of Non-Linear Output Frequency Response Functions With Application in Detection and Location of Damage in MDOF Structural Systems
,”
Int. J. Non-Linear Mech.
,
46
(
6
), pp.
841
853
.
29.
Feng
,
L.
,
Yi
,
X.
,
Zhu
,
D.
,
Xie
,
X.
, and
Wang
,
Y.
,
2015
, “
Damage Detection of Metro Tunnel Structure Through Transmissibility Function and Cross Correlation Analysis Using Local Excitation and Measurement
,”
Mech. Syst. Signal Process.
,
60–61
, pp.
59
74
.
30.
Lage
,
Y.
,
Neves
,
M.
,
Maia
,
N.
, and
Tcherniak
,
D.
,
2014
, “
Force Transmissibility Versus Displacement Transmissibility
,”
J. Sound Vib.
,
333
(
22
), pp.
5708
5722
.
31.
Meruane
,
V.
, and
Ortiz-Bernardin
,
A.
,
2015
, “
Structural Damage Assessment Using Linear Approximation With Maximum Entropy and Transmissibility Data
,”
Mech. Syst. Signal Process.
,
54–55
, pp.
210
223
.
32.
Frank
,
P. M.
, and
Ding
,
X.
,
1997
, “
Survey of Robust Residual Generation and Evaluation Methods in Observer-Based Fault Detection Systems
,”
J. Process Control
,
7
(
6
), pp.
403
424
.
33.
Collins
,
E. G.
, and
Song
,
T.
,
2000
, “
Robust H∞ Estimation and Fault Detection of Uncertain Dynamic Systems
,”
J. Guid. Control Dyn.
,
23
(
5
), pp.
857
864
.
34.
Aljanaideh
,
K. F.
, and
Bernstein
,
D. S.
,
2017
, “
Closed-Loop Identification of Unstable Systems Using Noncausal FIR Models
,”
Int. J. Control
,
90
(
2
), pp.
168
185
.
35.
Agüero
,
J. C.
, and
Goodwin
,
G. C.
,
2008
, “
Identifiability of Errors in Variables Dynamic Systems
,”
Automatica
,
44
(
2
), pp.
371
382
.
36.
Söderström
,
T.
,
2007
, “
Errors-in-Variables Methods in System Identification
,”
Automatica
,
43
(
6
), pp.
939
958
.
37.
Palanthandalam-Madapusi
,
H. J.
,
Van Pelt
,
T. H.
, and
Bernstein
,
D. S.
,
2010
, “
Parameter Consistency and Quadratically Constrained Errors-in-Variables Least-Squares Identification
,”
Int. J. Control
,
83
(
4
), pp.
862
877
.
38.
Aljanaideh
,
K. F.
, and
Bernstein
,
D. S.
,
2015
, “
Aircraft Sensor Health Monitoring Based on Transmissibility Operators
,”
J. Guid. Control Dyn.
,
38
(
8
), pp.
1492
1495
.
39.
Aljanaideh
,
K. F.
,
Coffer
,
B. J.
,
Dionne
,
D. S.
,
Kukreja
,
S. L.
, and
Bernstein
,
D. S.
,
2012
, “
Sensor-to-Sensor Identification for the SOFIA Testbed
,”
AIAA
Paper No. 2012-4814.
40.
Aljanaideh
,
K. F.
, and
Bernstein
,
D. S.
,
2016
, “
Experimental Application of Transmissibility Operators to Fault Detection
,”
American Control Conference
(
ACC
), Boston, MA, July 6–8, pp.
6833
6838
.
41.
Middleton
,
R. H.
, and
Goodwin
,
G. C.
,
1990
,
Digital Control and Estimation: A Unified Approach
,
Prentice Hall, Upper Saddle River, NJ
.
42.
Ljung
,
L.
,
1999
,
System Identification: Theory for the User
,
Prentice Hall
,
Upper Saddle River, NJ
.
43.
Forssell
,
U.
, and
Ljung
,
L.
,
1999
, “
Closed-Loop Identification Revisited
,”
Automatica
,
35
(
7
), pp.
1215
1241
.
44.
Forssell
,
U.
, and
Ljung
,
L.
,
2000
, “
A Projection Method for Closed-Loop Identification
,”
IEEE Trans. Autom. Control
,
45
(
11
), pp.
2101
2106
.
45.
Lee
,
T.-W.
,
Bell
,
A. J.
, and
Orglmeister
,
R.
,
1997
, “
Blind Source Separation of Real World Signals
,”
International Conference on Neural Networks
(
ICNN
), Houston, TX, June 9–12, pp.
2129
2134
.
46.
Ljung
,
L.
,
2002
, “
Prediction Error Estimation Methods
,”
Circuits Syst. Signal Process.
,
21
(
1
), pp.
11
21
.
47.
Söderström
,
T.
, and
Stoica
,
P.
,
1983
,
Instrumental Variable Methods for System Identification
,
Springer-Verlag
,
Berlin
.